文献速递神经儿科影像技术与安全MR

哈斯金斯儿童图谱:基于磁共振成像的儿童模板与图谱

The Haskins pediatric atlas: a magnetic-resonance-imaging-based pediatric template and atlas.
PubMed 文献 · Pediatr Radiol · 2020-11-19

研究利用72名7-14岁儿童的结构MRI数据,以非线性方法生成哈斯金斯儿童模板与图谱,并与成人模板及其他儿童模板比较形变距离与图谱分类准确性。结果显示该模板形变距离显著更小(P<0.0001),74%的脑区图谱分类正确率更高(P<0.0001),有助于儿童结构及功能影像分析。

要点

  • 哈斯金斯儿童模板较成人及其他儿童模板形变距离显著更小(P<0.0001),配准更准确。
  • 使用该模板时74%的脑区图谱分类正确率更高(P<0.0001),标签更精确。
  • 该模板基于72名7-14岁儿童结构MRI生成,适用于儿童群体fMRI研究。

核心结论

  • 哈斯金斯儿童模板因形变距离更低而使受试者间对应更准确,并提升图谱定位精度,有益于儿童群体结构及功能影像分析。

研究设计与样本

  • 采用非线性方法,基于72名7-14岁(中位10岁)儿童的结构MRI生成儿童模板及标注图谱区域的分区。
  • 通过多种形变距离与重叠度指标评估模板及图谱的准确性,并与成人模板及其他儿童模板比较。

关键影像表现/征象

  • 与成人模板及其他儿童模板相比,哈斯金斯儿童模板归一化儿童数据时的形变距离显著更小(P<0.0001)。
  • 使用哈斯金斯儿童模板时,74%的脑区图谱分类正确率更高(P<0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Spatial normalization plays an essential role in multi-subject MRI and functional MRI (fMRI) experiments by facilitating a common space in which group analyses are performed. Although many prominent adult templates are available, their use for pediatric data is problematic. Generalized templates for pediatric populations are limited or constructed using older methods that result in less ideal normalization.

OBJECTIVE: The Haskins pediatric templates and atlases aim to provide superior registration and more precise accuracy in labeling of anatomical and functional regions essential for all fMRI studies involving pediatric populations.

MATERIALS AND METHODS: The Haskins pediatric templates and atlases were generated with nonlinear methods using structural MRI from 72 children (age range 7-14 years, median 10 years), allowing for a detailed template with corresponding parcellations of labeled atlas regions. The accuracy of these templates and atlases was assessed using multiple metrics of deformation distance and overlap.

RESULTS: When comparing the deformation distances from normalizing pediatric data between this template and both the adult templates and other pediatric templates, we found significantly less deformation distance for the Haskins pediatric template (P<0.0001). Further, the correct atlas classification was higher using the Haskins pediatric template in 74% of regions (P<0.0001).

CONCLUSION: The Haskins pediatric template results in more accurate correspondence across subjects because of lower deformation distances. This correspondence also provides better accuracy in atlas locations to benefit structural and functional imaging analyses of pediatric populations.

来源:Pediatr Radiol,查看原文。版权归原作者所有。