脑动静脉畸形立体定向放射外科治疗后放射性影像学改变与脑水肿
回顾性队列研究纳入148例脑动静脉畸形患者共160个畸形血管团,接受直线粒子加速器立体定向放射外科治疗并随访MRI至少1年;40%出现新发T2/FLAIR高信号,峰值在12个月,影像学改变与新发神经系统症状显著相关,较大畸形最大径和多支供血动脉与影像学改变相关。
要点
- 40%的脑动静脉畸形在立体定向放射外科治疗后出现新发T2/FLAIR高信号,峰值约在12个月。
- 有影像学改变者69.2%出现新发神经系统症状,无影像学改变者仅9.5%(P = .0001)。
- 较大畸形最大径(P = .04)和多支供血动脉(P = .01)与放射性影像学改变相关。
诊断标准与关键数值
- 新发T2信号和FLAIR高信号见于40%的畸形血管团。
- T2 FLAIR体积在3、6、12、18、24个月分别为4.04、55.47、56.42、48.06、29.38 mL。
- 有放射性影像学改变者69.2%出现新发神经系统症状,无影像学改变者9.5%(P = .0001)。
- 影像学改变与新发神经系统表现显著相关(P < .001)。
- 较大畸形最大径(P = .04)和多支供血动脉(P = .01)与放射性影像学改变相关。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: T2 signal and FLAIR changes in patients undergoing stereotactic radiosurgery for brain AVMs may occur posttreatment and could result in adverse radiation effects. We aimed to evaluate outcomes in patients with these imaging changes, the frequency and degree of this response, and factors associated with it.
MATERIALS AND METHODS: Through this retrospective cohort study, consecutive patients treated with stereotactic radiosurgery for brain AVMs who had at least 1 year of follow-up MR imaging were identified. Logistic regression analysis was used to evaluate predictors of outcomes.
RESULTS: One-hundred-sixty AVMs were treated in 148 patients (mean, 35.6 years of age), including 42 (26.2%) pediatric AVMs. The mean MR imaging follow-up was 56.5 months. The median Spetzler-Martin grade was III. The mean maximal AVM diameter was 2.8 cm, and the mean AVM target volume was 7.4 mL. The median radiation dose was 16.5 Gy. New T2 signal and FLAIR hyperintensity were noted in 40% of AVMs. T2 FLAIR volumes at 3, 6, 12, 18, and 24 months were, respectively, 4.04, 55.47, 56.42, 48.06, and 29.38 mL Radiation-induced neurologic symptoms were encountered in 34.4%. In patients with radiation-induced imaging changes, 69.2% had new neurologic symptoms versus 9.5% of patients with no imaging changes (P = .0001). Imaging changes were significantly associated with new neurologic findings (P < .001). Larger AVM maximal diameter (P = .04) and the presence of multiple feeding arteries (P = .01) were associated with radiation-induced imaging changes.
CONCLUSIONS: Radiation-induced imaging changes are common following linear particle accelerator-based stereotactic radiosurgery for brain AVMs, appear to peak at 12 months, and are significantly associated with new neurologic findings.
引用
- Daou BJ, Palmateer G, Wilkinson DA, et al. Radiation-Induced Imaging Changes and Cerebral Edema following Stereotactic Radiosurgery for Brain AVMs. AJNR Am J Neuroradiol. 2020. PMID: 33214183. doi:10.3174/ajnr.A6880
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。