指南与共识技术与安全介入PET

关于近红外荧光成像与吲哚菁绿引导手术普遍应用的共识会议声明:一项改良德尔菲研究的结果

Consensus Conference Statement on the General Use of Near-infrared Fluorescence Imaging and Indocyanine Green Guided Surgery: Results of a Modified Delphi Study.
指南 / 共识 · Ann Surg · 2022-01-01

该共识声明基于2019年9月8日在德国法兰克福举行的1天共识会议,对19名国际荧光引导手术专家进行两轮匿名投票的改良德尔菲调查,共识阈值设为70%、投票稳健性阈值设为80%。专家在44条声明中达成41条共识,强烈认为近红外荧光引导手术在多种临床场景中有效且安全,但确定吲哚菁绿的最佳剂量、浓度、给药途径和时机仍需持续研究。

要点

  • 近红外荧光引导手术在定位血管等关键解剖结构、检测肿瘤和前哨淋巴结、评估组织灌注和吻合口漏、勾画分叶器官及定位甲状旁腺等场景中被强烈共识为有效且安全。
  • 专家认为吲哚菁绿的最小和最大安全有效剂量分别为1至2 mg和大于10 mg。
  • 确定吲哚菁绿的最佳剂量、浓度、给药途径和时机应作为持续的研究重点已达成强烈共识。

诊断标准与关键数值

  • 专家来自5大洲,在44条声明中达成41条共识。
  • 强烈共识认为近红外荧光引导手术在广泛临床场景中有效且安全,包括定位血管等关键解剖结构、检测肿瘤和前哨淋巴结、评估组织灌注和吻合口漏、勾画分叶器官及定位甲状旁腺。
  • 专家认为吲哚菁绿的最小和最大安全有效剂量分别为1至2 mg和大于10 mg。
  • 强烈共识认为确定吲哚菁绿的最佳剂量、浓度、给药途径和时机应作为持续的研究重点。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: In recent decades, the use of near-infrared light and fluorescence-guidance during open and laparoscopic surgery has exponentially expanded across various clinical settings. However, tremendous variability exists in how it is performed.

OBJECTIVE: In this first published survey of international experts on fluorescence-guided surgery, we sought to identify areas of consensus and nonconsensus across 4 areas of practice: fundamentals; patient selection/preparation; technical aspects; and effectiveness and safety.

METHODS: A Delphi survey was conducted among 19 international experts in fluorescence-guided surgery attending a 1-day consensus meeting in Frankfurt, Germany on September 8th, 2019. Using mobile phones, experts were asked to anonymously vote over 2 rounds of voting, with 70% and 80% set as a priori thresholds for consensus and vote robustness, respectively.

RESULTS: Experts from 5 continents reached consensus on 41 of 44 statements, including strong consensus that near-infrared fluorescence-guided surgery is both effective and safe across a broad variety of clinical settings, including the localization of critical anatomical structures like vessels, detection of tumors and sentinel nodes, assessment of tissue perfusion and anastomotic leaks, delineation of segmented organs, and localization of parathyroid glands. Although the minimum and maximum safe effective dose of ICG were felt to be 1 to 2 mg and >10 mg, respectively, there was strong consensus that determining the optimum dose, concentration, route and timing of ICG administration should be an ongoing research focus.

CONCLUSIONS: Although fluorescence imaging was almost unanimously perceived to be both effective and safe across a broad range of clinical settings, considerable further research remains necessary to optimize its use.

来源:Ann Surg,查看原文。版权归原作者所有。

引用

  1. Dip F, Boni L, Bouvet M, et al. Consensus Conference Statement on the General Use of Near-infrared Fluorescence Imaging and Indocyanine Green Guided Surgery: Results of a Modified Delphi Study. Ann Surg. 2022. PMID: 33214476. doi:10.1097/SLA.0000000000004412

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。