指南与共识胸部CT

北美放射学会(RSNA)关于COVID-19胸部CT表现的专家共识声明与CO-RADS的比较:胸部放射科医师报告系统性能与最终用户偏好

Radiological Society of North America (RSNA) Expert Consensus Statement Related to Chest CT Findings in COVID-19 Versus CO-RADS: Comparison of Reporting System Performance Among Chest Radiologists and End-User Preference.
指南 / 共识 · Can Assoc Radiol J · 2020-11-03

回顾性分析279例疑似COVID-19并接受RT-PCR检测患者的胸部CT,由3名胸部放射科医师独立按RSNA与CO-RADS系统判读。两系统观察者间/内一致性几乎完美(Fleiss kappa 0.871–0.876与0.90–0.92),CO-RADS特异度更高(68–73% vs RSNA 52–58%)。60名临床医生调查中多数偏好RSNA报告系统(66.7–76.7%,P<0.05)。

要点

  • RSNA与CO-RADS两系统观察者间一致性几乎完美(Fleiss kappa 0.871与0.876,P<0.0001)。
  • CO-RADS特异度68–73%,高于RSNA的52–58%;两系统阴性预测值相似(0.573–0.585与0.573–0.58)。
  • 60名调查参与者中多数对所有选项均偏好RSNA报告系统(66.7–76.7%,P<0.05)。

诊断标准与关键数值

  • 观察者间一致性:RSNA Fleiss kappa 0.871(P<0.0001),CO-RADS Fleiss kappa 0.876(P<0.0001)。
  • 观察者内一致性(两评分系统等效类别间):Fleiss kappa 0.90–0.92(P<0.001)。
  • 阳性预测值:RSNA 0.798–0.818,CO-RADS 0.891–0.903。
  • 阴性预测值:RSNA 0.573–0.585,CO-RADS 0.573–0.58。
  • 特异度:CO-RADS 68–73%,RSNA 52–58%,CO-RADS特异度更高。

临床应用与阅片要点

  • RSNA与CO-RADS报告系统均可提供标准化描述,观察者间/内一致性几乎完美且阳性预测值高。
  • CO-RADS特异度68–73%高于RSNA的52–58%,两系统阴性预测值相似(0.573–0.585与0.573–0.58)。
  • 60名调查参与者中多数对所有选项均偏好RSNA报告系统(66.7–76.7%,P<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The RSNA expert consensus statement and CO-RADS reporting system assist radiologists in describing lung imaging findings in a standardized manner in patients under investigation for COVID-19 pneumonia and provide clarity in communication with other healthcare providers. We aim to compare diagnostic performance and inter-/intra-observer among chest radiologists in the interpretation of RSNA and CO-RADS reporting systems and assess clinician preference.

METHODS: Chest CT scans of 279 patients with suspected COVID-19 who underwent RT-PCR testing were retrospectively and independently examined by 3 chest radiologists who assigned interpretation according to the RSNA and CO-RADS reporting systems. Inter-/intra-observer analysis was performed. Diagnostic accuracy of both reporting systems was calculated. 60 clinicians participated in a survey to assess end-user preference of the reporting systems.

RESULTS: Both systems demonstrated almost perfect inter-observer agreement (Fleiss kappa 0.871, P < 0.0001 for RSNA; 0.876, P < 0.0001 for CO-RADS impressions). Intra-observer agreement between the 2 scoring systems using the equivalent categories was almost perfect (Fleiss kappa 0.90-0.92, P < 0.001). Positive predictive values were high, 0.798-0.818 for RSNA and 0.891-0.903 CO-RADS. Negative predictive value were similar, 0.573-0.585 for RSNA and 0.573-0.58 for CO-RADS. Specificity differed between the 2 systems, 68-73% for CO-RADS and 52-58% for RSNA with superior specificity of CO-RADS. Of 60 survey participants, the majority preferred the RSNA reporting system rather than CO-RADS for all options provided (66.7-76.7%; P < 0.05).

CONCLUSIONS: RSNA and CO-RADS reporting systems are consistent and reproducible with near perfect inter-/intra-observer agreement and excellent positive predictive value. End-users preferred the reporting language in the RSNA system.

来源:Can Assoc Radiol J,查看原文。版权归原作者所有。

引用

  1. O' Neill SB, Byrne D, Müller NL, et al. Radiological Society of North America (RSNA) Expert Consensus Statement Related to Chest CT Findings in COVID-19 Versus CO-RADS: Comparison of Reporting System Performance Among Chest Radiologists and End-User Preference. Can Assoc Radiol J. 2020. PMID: 33138634. doi:10.1177/0846537120968919

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。