基于骨盆X线摄影与深度学习算法自动测量髋关节的可行性研究
本研究纳入1260张骨盆正位X线片,用1060张训练验证、200张测试,开发编码器-解码器卷积神经网络输出多通道热图,自动测量髋关节四个参数。模型在3mm阈值下关键点正确率87%–100%,与三位放射科医生参考标准间ICC 0.83–0.93、r 0.83–0.93,结论认为该模型能准确识别标志点并自动生成髋关节参数。
要点
- 模型在3 mm距离阈值下关键点正确率(PCK)为87%–100%。
- 左髋CE角、Tönnis角、Sharp角、股骨头挤出指数分别为29.8°±6.1°、5.6°±4.2°、39.0°±3.5°、19%±5%。
- 右髋对应参数分别为30.4°±6.1°、7.1°±4.4°、38.9°±3.7°、18%±5%。
核心结论
- 基于深度学习算法的新模型能准确识别骨盆正位X线片上的标志点并自动生成髋关节参数,为临床测量提供便利。
研究设计与样本
- 共纳入1260张骨盆正位X线片,随机抽取1060张用于训练和验证,200张作为测试集;开发编码器-解码器卷积神经网络输出多通道热图;以三位放射科医生测量各参数均值为参考标准;左右髋分别分析。
诊断标准与关键数值
- 模型与参考标准间四种参数的一致性:ICC 0.83–0.93,Pearson相关系数r 0.83–0.93,均方根误差RMSE 0.02–3.27,平均绝对误差MAE 0.02–1.79;关键点正确率PCK在3 mm距离阈值范围为87%–100%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To develop and evaluate an automatic measurement model for hip joints based on anteroposterior (AP) pelvic radiography and a deep learning algorithm.
METHODS: A total of 1260 AP pelvic radiographs were included. 1060 radiographs were randomly sampled for training and validation and 200 radiographs were used as the test set. Landmarks for four commonly used parameters, such as the center-edge (CE) angle of Wiberg, Tönnis angle, sharp angle, and femoral head extrusion index (FHEI), were identified and labeled. An encoder-decoder convolutional neural network was developed to output a multi-channel heat map. Measurements were obtained through landmarks on the test set. Right and left hips were analyzed respectively. The mean of each parameter obtained by three radiologists was used as the reference standard. The Percentage of Correct Key points (PCK), intraclass correlation coefficient (ICC), Pearson correlation coefficient (r), root mean square error (RMSE), mean absolute error (MAE), and Bland-Altman plots were used to determine the performance of deep learning algorithm.
RESULTS: PCK of the model at 3 mm distance threshold range was from 87 % to 100 %. The CE angle, Tönnis angle, Sharp angle and FHEI of the left hip generated by the model were 29.8°±6.1°, 5.6°±4.2°, 39.0°±3.5° and 19 %±5 %, respectively. The parameters of the right hip were 30.4°±6.1°, 7.1°±4.4°, 38.9°±3.7° and 18 %±5 %. There were good correlation and consistency of the four parameters between the model and the reference standard (ICC 0.83-0.93, r 0.83-0.93, RMSE 0.02-3.27, MAE 0.02-1.79).
CONCLUSIONS: The new developed model based on deep learning algorithm can accurately identify landmarks on AP pelvic radiography and automatically generate parameters of hip joint. It will provide convenience for clinical practice of measurement.
引用
- Yang W, Ye Q, Ming S, et al. Feasibility of automatic measurements of hip joints based on pelvic radiography and a deep learning algorithm. Eur J Radiol. 2020. PMID: 33017773. doi:10.1016/j.ejrad.2020.109303
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。