床旁超声在儿童骨折检测中的准确性:一项验证研究
这项前瞻性、非随机、方便抽样研究在五个医疗中心比较床旁超声(POCUS)与常规X线检测儿童骨折,共554次检查。高技能操作者POCUS的敏感度91.67%、特异度88.89%、Cohen κ 0.81,标准技能操作者敏感度71.50%、特异度82.91%、κ 0.54。作者指出高技能操作者POCUS诊断准确性良好。
要点
- 高技能操作者POCUS敏感度91.67%、特异度88.89%,与X线一致性κ 0.81。
- 标准技能操作者POCUS敏感度71.50%、特异度82.91%,一致性κ 0.54。
- 研究部位以四肢和手/足为主,胸部占3.54%。
核心结论
- POCUS在评估骨折方面具有良好的诊断准确性,高技能操作者表现出极好的敏感度、特异度、阳性预测值和阴性预测值。
研究设计与样本
- 前瞻性、非随机、方便抽样研究,在五个医疗中心进行,评估儿童创伤患者。
- 共进行554次POCUS和X线检查,POCUS和X线结果作为二分类变量(骨折存在或不存在)。
- 计算患病率、敏感度、特异度、阳性预测值和阴性预测值及95%CI,并以Cohen κ系数衡量一致性。
关键影像表现/征象
- 体格检查中肿胀、局部血肿和功能受限分别见于66.73%、33.78%和53.74%的参与者。
- 研究部位以四肢和手/足最多(58.19%和38.27%),胸部较少(3.54%)。
诊断标准与关键数值
- 高技能操作者POCUS敏感度91.67%(95%CI 76.41-97.82%),特异度88.89%(95%CI 73.00-96.34%)。
- 高技能操作者阳性预测值89.19%(95%CI 73.64-96.48%),阴性预测值91.43%(95%CI 75.81-97.76%),Cohen κ 0.81。
- 标准技能操作者POCUS敏感度71.50%(95%CI 64.75-77.43%),特异度82.91%(95%CI 77.82-87.06%)。
- 标准技能操作者阳性预测值75.90%(95%CI 69.16-81.59%),阴性预测值79.44%(95%CI 74.21-83.87%),Cohen κ 0.54。
临床应用与阅片要点
- 高技能操作者POCUS诊断儿童骨折准确性良好,敏感度、特异度和预测值均较高,与X线一致性很好(κ 0.81)。
- 标准技能操作者POCUS敏感度71.50%、一致性中等(κ 0.54),解读结果时需结合操作者技能水平。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
This study sought to compare point-of-care ultrasound (POCUS) and conventional X-rays for detecting fractures in children. This was a prospective, non-randomized, convenience-sample study conducted in five medical centers. It evaluated pediatric patients with trauma. POCUS and X-ray examination results were treated as dichotomous variables with fracture either present or absent. Descriptive statistics were calculated in addition to prevalence, sensitivity, specificity, positive predictive value and negative predictive value, including 95% confidence intervals (CIs). The Cohen κ coefficient was determined as a measurement of the level of agreement. A total of 554 examinations were performed with POCUS and X-ray. On physical examination, swelling, localized hematoma and functional limitation were found in 66.73%, 33.78% and 53.74% of participants, respectively. The most-studied areas were limbs and hands/feet (58.19% and 38.27%), whereas the thorax was less represented (3.54%). Sensitivity of POCUS was 91.67% (95% CI, 76.41-97.82%) for high-skill providers and 71.50 % (95% CI, 64.75-77.43%) for standard-skill providers. Specificity was 88.89% (95% CI, 73.00-96.34%) and 82.91% (95% CI, 77.82-87.06%) for high- and standard-skill providers, respectively. Positive predictive value was 89.19% (95% CI, 73.64-96.48%) and 75.90% (95% CI, 69.16-81.59%) for high- and standard-skill providers, respectively. Negative predictive value was 91.43% (95% CI, 75.81-97.76%) and 79.44% (95% CI, 74.21-83.87%) for high- and standard-skill providers, respectively. The Cohen κ coefficient showed very good agreement (0.81) for high-skill providers, but moderate agreement (0.54) for standard-skill providers. We noted good diagnostic accuracy of POCUS in evaluating fracture, with excellent sensitivity, specificity, and positive and negative predictive value for high-skill providers.
引用
- Caroselli C, Raffaldi I, Norbedo S, et al. Accuracy of Point-of-Care Ultrasound in Detecting Fractures in Children: A Validation Study. Ultrasound Med Biol. 2020. PMID: 33097313. doi:10.1016/j.ultrasmedbio.2020.09.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。