非对比静息间期切片选择性(QISS)MRA联合基于MRI的血管钙化可视化评估下肢外周动脉疾病患者动脉狭窄的诊断准确性
前瞻性纳入26例下肢外周动脉疾病患者,在DSA前完成下肢CTA及1.5-T或3-T PDIP-SOS/QISS MRI,比较QISS MRA(联合或不联合钙化可视化)与CTA对≥50%狭窄的诊断准确性。QISS MRA联合PDIP-SOS后敏感度、特异度和AUC分别为92.2%、93.2%和0.928,AUC较单纯QISS MRA显著提高(p=0.0266),诊断准确性与CTA相当,但图像质量仍低于CTA。
要点
- QISS MRA联合PDIP-SOS钙化可视化后,≥50%狭窄的AUC由0.879升至0.928,显著提高(p=0.0266)。
- 联合方案的敏感度92.2%、特异度93.2%,与CTA的90.2%、94.2%接近,AUC 0.928对0.923。
- PDIP-SOS与NCCT钙化定量高度相关(r=0.77),但两者存在显著差异(p=0.0002)。
核心结论
- QISS MRA联合PDIP-SOS MRI对下肢外周动脉疾病狭窄检测的准确性提高,与CTA相当,但图像质量仍低于CTA。
研究设计与样本
- 前瞻性纳入26例外周动脉疾病患者(70±8岁),在DSA前接受下肢CTA及1.5-T或3-T PDIP-SOS/QISS MRI检查。
- 以DSA为参考标准,两名阅片者评估图像质量并对QISS MRA(联合或不联合钙化可视化)进行≥50%狭窄分级。
- 钙化定量在MRI与平扫CT(NCCT)间采用配对t检验、Pearson相关和Bland-Altman分析比较。
关键影像表现/征象
- PDIP-SOS可提供外周动脉钙化可视化,联合QISS MRA用于评估动脉狭窄。
- QISS MRA图像质量评分为3.0(3.0-4.0),CTA为4.0(3.0-4.0),CTA显著更高(p=0.0369)。
诊断标准与关键数值
- 以DSA为参考,QISS MRA检测≥50%狭窄的敏感度85.4%、特异度90.3%、AUC 0.879。
- QISS MRA联合PDIP-SOS检测≥50%狭窄的敏感度92.2%、特异度93.2%、AUC 0.928。
- CTA检测≥50%狭窄的敏感度90.2%、特异度94.2%、AUC 0.923。
- 加入PDIP-SOS后AUC显著提高(p=0.0266)。
- PDIP-SOS与NCCT钙化定量分别为80.6±31.2 mm3和88.0±29.8 mm3,差异显著(p=0.0002),相关性高(r=0.77,p<0.0001),平均差值-7.4 mm3。
临床应用与阅片要点
- 在非对比QISS MRA方案中联合PDIP-SOS钙化可视化,可提高对≥50%狭窄的检出准确性与阅片者间一致性。
- PDIP-SOS钙化定量与NCCT高度相关但存在系统差异,解读钙化负荷时需注意两种方法不可直接互换。
- QISS MRA图像质量低于CTA,阅片时需结合钙化信息综合判断狭窄程度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The proton density-weighted, in-phase stack-of-stars (PDIP-SOS) MRI technique provides calcification visualization in peripheral artery disease (PAD). This study sought to investigate the diagnostic accuracy of a combined non-contrast quiescent-interval slice-selective (QISS) MRA and PDIP-SOS MRI protocol for the detection of PAD, in comparison with CTA and digital subtraction angiography (DSA).
METHODS: Twenty-six prospectively enrolled PAD patients (70 ± 8 years) underwent lower extremity CTA and 1.5-T or 3-T PDIP-SOS/QISS MRI prior to DSA. Two readers rated image quality and graded stenosis (≥ 50%) on QISS MRA without/with calcification visualization. Sensitivity, specificity, and area under the curve (AUC) were calculated against DSA. Calcification was quantified and compared between MRI and non-contrast CT (NCCT) using paired t test, Pearson's correlation, and Bland-Altman analysis.
RESULTS: Image quality ratings were significantly higher for CTA compared to those for MRA (4.0 [3.0-4.0] and 3.0 [3.0-4.0]; p = 0.0369). The sensitivity and specificity of QISS MRA, QISS MRA with PDIP-SOS, and CTA for ≥ 50% stenosis detection were 85.4%, 92.2%, and 90.2%, and 90.3%, 93.2%, and 94.2%, respectively, while AUCs were 0.879, 0.928, and 0.923, respectively. A significant increase in AUC was observed when PDIP-SOS was added to the MRA protocol (p = 0.0266). Quantification of calcification showed significant differences between PDIP-SOS and NCCT (80.6 ± 31.2 mm3 vs. 88.0 ± 29.8 mm3; p = 0.0002) with high correlation (r = 0.77, p < 0.0001) and moderate mean of differences (- 7.4 mm3).
CONCLUSION: QISS MRA combined with PDIP-SOS MRI provides improved, CTA equivalent, accuracy for the detection of PAD, although its image quality remains inferior to CTA.
KEY POINTS: • Agreement in stenosis detection rate using non-contrast quiescent-interval slice-selective MRA compared to DSA improved when calcification visualization was provided to the readers. • An increase was observed in both sensitivity and specificity for the detection of ≥ 50% stenosis when MRI-based calcification assessment was added to the protocol, resulting in a diagnostic accuracy more comparable to CTA. • Quantification of calcification showed statistical difference between MRI and non-contrast CT; however, a high correlation was observed between the techniques.
引用
- Varga-Szemes A, Penmetsa M, Emrich T, et al. Diagnostic accuracy of non-contrast quiescent-interval slice-selective (QISS) MRA combined with MRI-based vascular calcification visualization for the assessment of arterial stenosis in patients with lower extremity peripheral artery disease. Eur Radiol. 2020. PMID: 33068186. doi:10.1007/s00330-020-07386-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。