同步非增强血管造影与斑块内出血成像(SNAP)表征颈动脉斑块内出血的组织学验证
本研究以35例因颈动脉粥样硬化性疾病行颈动脉内膜切除术的患者为对象,采用3.0-T磁共振采集SNAP与MP-RAGE序列,并以组织学为参考标准验证两者识别和量化颈动脉斑块内出血的表现。结果显示SNAP识别IPH的准确度、敏感度、特异度分别为86.7%、85%、89.6%,MP-RAGE分别为76.6%、75%、79.2%;SNAP与组织学测值相关性更强、偏倚更小,提示SNAP在识别和量化颈动脉IPH方面优于传统MP-RAGE序列。
要点
- SNAP识别颈动脉IPH的准确度86.7%、敏感度85%、特异度89.6%,高于MP-RAGE的76.6%、75%、79.2%。
- SNAP与组织学识别IPH的kappa值为0.725,MP-RAGE与组织学为0.520。
- 小尺寸IPH时SNAP与组织学的一致性更好,富含脂质池或疏松基质及慢性陈旧性IPH可致假阳性与假阴性。
诊断标准与关键数值
- SNAP识别IPH的准确度86.7%、敏感度85%、特异度89.6%、阳性预测值93.2%、阴性预测值78.2%。
- MP-RAGE识别IPH的准确度76.6%、敏感度75%、特异度79.2%、阳性预测值85.7%、阴性预测值65.5%。
- SNAP与组织学识别IPH的kappa值为0.725,MP-RAGE与组织学为0.520。
- 测量IPH面积时SNAP与组织学相关性r=0.805(p<0.001),MP-RAGE与组织学r=0.637(p<0.001)。
- Bland-Altman分析示SNAP测量IPH面积偏倚1.4 mm2(95%CI:-0.016至2.883),MP-RAGE偏倚1.7 mm2(95%CI:-0.039至3.430)。
局限性
- 富含脂质池或疏松基质及慢性陈旧性IPH(胆固醇结晶)可导致SNAP与MP-RAGE识别IPH时出现假阳性和假阴性结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study sought to validate the performance of simultaneous non-contrast angiography and intraplaque hemorrhage (SNAP) imaging in characterizing carotid IPH by histology.
METHODS: Thirty-five patients with carotid atherosclerotic disease (symptomatic 50-70% stenosis or > 70% stenosis) scheduled for carotid endarterectomy underwent 3.0-T carotid MR imaging by acquiring SNAP and magnetization-prepared rapid acquisition gradient-echo (MP-RAGE) sequences. Presence and area of IPH were separately evaluated on SNAP and MP-RAGE images. Presence and area of IPH were also assessed on histology. Agreement between SNAP/MP-RAGE and histology was determined in identify and quantify IPH using Cohen kappa, Spearman correlation, and Bland-Altman analyses.
RESULTS: Of all 35 patients (mean age: 63.1 ± 8.8 years; 27 males), 128 slices with successful registration were eligible for analysis. The accuracy, sensitivity, specificity, and positive and negative predictive values were 86.7%, 85%, 89.6%, 93.2%, and 78.2% for SNAP, and 76.6%, 75%, 79.2%, 85.7%, and 65.5% for MP-RAGE in identification of IPH, respectively. In identification of IPH, the kappa value between SNAP and histology and between MP-RAGE and histology was 0.725 and 0.520, respectively. The correlation between SNAP and histology (r = 0.805, p < 0.001) was stronger than that between MP-RAGE and histology (r = 0.637, p < 0.001) in measuring IPH area. Bland-Altman analysis showed that, in measuring IPH area, the bias of SNAP (1.4 mm2, 95% CI: - 0.016 to 2.883) was smaller than that of MP-RAGE (1.7 mm2, 95% CI: - 0.039 to 3.430) compared with histology.
CONCLUSIONS: This validation study by histology demonstrates that SNAP sequence better identifies and quantifies carotid intraplaque hemorrhage compared with traditional MP-RAGE sequence.
KEY POINTS: • SNAP imaging showed better agreement with histology compared with MP-RAGE imaging, especially for the IPHs with small size. • SNAP sequence is a more effective tool to identify and quantify carotid IPH than traditional sequence of MP-RAGE that can help clinicians to optimizing the treatment strategy. • The plaque components of rich lipid pools or loose matrix and chronic/old IPH (cholesterol crystals) can lead to false positive and false negative results in SNAP and MP-RAGE imaging for identifying IPH.
引用
- Li D, Qiao H, Han Y, et al. Histological validation of simultaneous non-contrast angiography and intraplaque hemorrhage imaging (SNAP) for characterizing carotid intraplaque hemorrhage. Eur Radiol. 2020. PMID: 33052465. doi:10.1007/s00330-020-07352-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。