文献速递神经外周血管USDSA

症状性颈动脉近闭塞患者的多中心注册研究:超声与血流动力学特征

Ultrasonographic and hemodynamic characteristics of patients with symptomatic carotid near-occlusion: results from a multicenter registry study.
PubMed 文献 · Neuroradiology · 2020-10-06

这项前瞻性、观察性、全国性多中心研究纳入135例DSA证实的颈动脉近闭塞患者,评估超声与DSA诊断的一致性及血流动力学特征。超声与DSA诊断仅44%一致,不一致与是否完全塌陷有关;患侧大脑中动脉平均流速和搏动指数显著低于对侧,66%病例脑血流反应性减低或耗竭。

要点

  • 超声与DSA诊断颈动脉近闭塞仅44%一致,完全塌陷者45%被超声误判为完全闭塞,无完全塌陷者40%被误判为重度狭窄。
  • 患侧大脑中动脉平均流速43 cm/s低于对侧58 cm/s,搏动指数0.80低于对侧1.00,均p<0.001。
  • 92%患者存在侧支循环,以前交通动脉最常见(73%);66%病例脑血流反应性减低或耗竭。

关键影像表现/征象

  • 超声与DSA诊断颈动脉近闭塞仅44%一致,不一致与完全塌陷的有无相关。
  • 存在完全塌陷的颈动脉近闭塞患者中45%被超声归类为颈动脉完全闭塞。
  • 无完全塌陷的颈动脉近闭塞患者中40%被超声判读为重度狭窄(p<0.001)。
  • 92%患者检出侧支循环,前交通动脉最常见(73%)。
  • 66%病例脑血流反应性减低或耗竭。

诊断标准与关键数值

  • 以DSA证实的颈动脉近闭塞为参考标准,颈动脉超声诊断一致性仅44%。
  • 患侧大脑中动脉平均流速43 cm/s vs 对侧58 cm/s(p<0.001),搏动指数0.80 vs 对侧1.00(p<0.001)。
  • 侧支网络差或缺失者脑血流反应性减低或耗竭占82%,侧支动脉≥2条者占56%(p=0.051)。

临床应用与阅片要点

  • 颈动脉近闭塞的超声诊断与DSA差异明显,完全塌陷者易被判为完全闭塞、无完全塌陷者易被判为重度狭窄。
  • 阅片时可结合患侧大脑中动脉平均流速与搏动指数减低、脑血流反应性减低或耗竭等血流动力学征象综合判断。
  • 侧支循环以 originating 前交通动脉最常见,侧支网络差或缺失者脑血流反应性减低或耗竭更常见(82% vs 56%,p=0.051)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The ultrasonographic and hemodynamic features of patients with carotid near-occlusion (CNO) are still not well known. Our aim was to describe the ultrasonographic and hemodynamic characteristics of a cohort of patients with CNO.

METHODS: A prospective, observational, nationwide, and multicenter study was conducted from January/2010 to May/2016. Patients with digital subtraction angiography (DSA)-confirmed CNO were included. We collected information on clinical and demographic characteristics, carotid and transcranial ultrasonography and DSA findings, presence of full-collapse, collateral circulation, and cerebrovascular reactivity (CVR).

RESULTS: One hundred thirty-five patients were analyzed. Ultrasonographic and DSA diagnosis of CNO were concordant in only 44%. This disagreement was related to the presence/absence of full-collapse: 45% of patients with CNO with full-collapse were classified as a complete carotid occlusion, and 40% with a CNO without full-collapse were interpreted as severe stenosis (p < 0.001). Mean velocities (mV) and pulsatility indexes (PIs) were significantly lower in the ipsilateral middle cerebral artery compared with the contralateral (43 cm/s vs 58 cm/s, p < 0.001; 0.80 vs 1.00, p < 0.001). Collateral circulation was identified in 92% of patients, with the anterior communicating artery (73%) being the most frequent. CVR was decreased or exhausted in 66% of cases and was more frequent in patients with a poor or absent collateral network compared with patients with ≥ 2 collateral arteries (82% vs 56%, p = 0.051).

CONCLUSION: The accuracy of carotid ultrasonography in the diagnosis of CNO seems to be limited, with significant discrepancies with DSA. Decreased ipsilateral mV, PI, and CVR suggest a hemodynamic compromise in patients with CNO.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Palacios-Mendoza MA, García-Pastor A, Gil-Núñez A, et al. Ultrasonographic and hemodynamic characteristics of patients with symptomatic carotid near-occlusion: results from a multicenter registry study. Neuroradiology. 2020. PMID: 33025041. doi:10.1007/s00234-020-02567-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。