文献速递神经骨肌MR

对比增强三维反转恢复磁共振神经成像用于评估臂丛分支神经

Post-Contrast 3D Inversion Recovery Magnetic Resonance Neurography for Evaluation of Branch Nerves of the Brachial Plexus.
PubMed 文献 · Eur J Radiol · 2020-09-28

研究纳入18例患者,在3.0T下同次检查分别采集增强前与增强后3D STIR-FSE序列,由3名肌骨放射科医师评估血管信号抑制、腋神经、肌皮神经和肩胛上神经显示、诊断信心及病灶清晰度。增强后STIR显著改善血管信号抑制(OR=209.9)、神经显示(OR=8.4)和诊断信心(OR=13.2),C6神经-肌肉信号强度比平均增加24%(p=0.017)。

要点

  • 增强后3D STIR-FSE显著改善臂丛分支神经显示与诊断信心。
  • 增强后血管信号抑制显著改善(OR=209.9,95%CI 21.0-2094.6)。
  • C6神经-肌肉信号强度比平均增加24%(p=0.017)。

关键影像表现/征象

  • 增强后STIR血管信号抑制较增强前显著改善(OR=209.9,95%CI 21.0-2094.6,p<.001)。
  • 增强后STIR在所有神经节段显著改善神经显示(OR=8.4,95%CI 3.6-19.9,p<.001)。
  • 增强后STIR在所有神经节段显著改善诊断信心(OR=13.2,95%CI 4.8-36.0,p<.001)。
  • 增强后STIR病灶清晰度提高1分,但未达统计学显著(Reader 1:p=0.5,Reader 2:p=0.063)。
  • 定量分析显示增强后STIR的C6神经-肌肉信号强度比平均增加24%(p=0.017)。

诊断标准与关键数值

  • 增强后STIR神经显示评估者间一致性系数0.74-1.0,评估者内0.94-1.0。
  • 增强后STIR诊断信心评估者间一致性系数0.79-1.0,评估者内0.94-1.0。

临床应用与阅片要点

  • 增强后3D STIR-FSE可用于改善臂丛分支神经的血管信号抑制和神经显示。
  • 增强后STIR提高诊断信心,但病灶清晰度提升未达统计学显著(Reader 1 p=0.5,Reader 2 p=0.063)。

局限性

  • 病灶清晰度改善未达统计学显著(Reader 1:p=0.5,Reader 2:p=0.063)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare 3.0 Tesla brachial plexus three-dimensional (3D) T2-weighted short tau inversion recovery fast spin echo (STIR-FSE) MRI sequences before (pre-contrast STIR) and after (post-contrast STIR) administration of gadolinium intravenous contrast.

METHOD: Eighteen patients were included. Each patient was imaged before and after intravenous contrast administration during the same session. 3D STIR-FSE sequences were obtained at 3.0 Tesla using two 16-channel flexible coils positioned over the lower neck and chest wall region. Three musculoskeletal radiologists qualitatively assessed degree of vascular signal suppression, visualization of the axillary, musculocutaneous, and suprascapular nerves, diagnostic confidence in nerve evaluation, and lesion conspicuity. Marginal ordinal logistic regression models were used to compare subjective ratings between sequences. Pre- and post-STIR lesion conspicuity was compared using Wilcoxon signed-rank test. Inter- and intra-observer agreements were assessed using Gwet's agreement coefficient.

RESULTS: Vascular signal suppression significantly improved following contrast administration (odds ratio, OR = 209.9, 95% confidence interval, CI: 21.0-2094.6, p < .001). The post-contrast STIR technique significantly improved nerve visualization (OR = 8.4, 95% CI: 3.6-19.9, p < .001) and diagnostic confidence in evaluation (OR = 13.2, 95% CI: 4.8-36.0, p < .001) across all nerve segments. Post-contrast STIR improved lesion conspicuity by 1 point, but statistical significance was not reached (Reader 1: p = 0.5, Reader 2: p = 0.063). Post-contrast STIR imaging demonstrated substantial to near-perfect inter- and intra-rater agreement coefficients for both nerve visualization (inter-rater: 0.74-1.0, intra-rater: 0.94-1.0) and diagnostic confidence (inter-rater: 0.79-1.0, intra-rater: 0.94-1.0). Quantitatively, post-contrast STIR demonstrated a 24% increase in mean C6 nerve-to-muscle signal intensity ratio (p = 0.017).

CONCLUSIONS: Post-contrast STIR improved nerve-to-muscle contrast ratio, allowing for enhanced visualization and diagnostic confidence in evaluation of branch nerves of the brachial plexus.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Sneag DB, Daniels SP, Geannette C, et al. Post-Contrast 3D Inversion Recovery Magnetic Resonance Neurography for Evaluation of Branch Nerves of the Brachial Plexus. Eur J Radiol. 2020. PMID: 33035919. doi:10.1016/j.ejrad.2020.109304

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。