文献速递骨肌CTMR

双能CT检测急性膝关节损伤患者骨髓水肿的诊断准确性:系统评价与Meta分析

Diagnostic accuracy of dual-energy CT for detecting bone marrow edema in patients with acute knee injuries: a systematic review and meta-analysis.
PubMed 文献 · Skeletal Radiol · 2020-10-22

该系统评价与Meta分析纳入8项研究共267例急性膝关节损伤成人患者,评估双能CT(DECT)以MRI为参考标准检测骨髓水肿(BME)的诊断准确性。汇总敏感度84%(95%CI 74-91%)、特异度96%(95%CI 93-98%)、AUROC 0.97(95%CI 0.95-0.98)。作者认为DECT检测BME具有特异性且准确,可作为MRI的替代方法,尤其当MRI禁忌或不可用时。

要点

  • DECT检测急性膝关节损伤骨髓水肿的汇总敏感度84%、特异度96%、AUROC 0.97。
  • 基于骨的特征描述特异度低于基于区域的描述(83% vs 97%,p<0.05),敏感度无差异。
  • 多数研究偏倚风险与适用性关注均为低风险。

核心结论

  • DECT检测成人急性膝关节损伤患者的骨髓水肿具有特异性且准确,可作为MRI的替代方法,尤其当MRI禁忌或不可用时。

研究设计与样本

  • 系统评价与Meta分析,遵循PRISMA-DTA指南,检索MEDLINE、EMBASE、Scopus、Cochrane Library及灰色文献,检索时间从建库至2020年1月31日。
  • 纳入评估DECT检测急性膝关节损伤骨髓水肿诊断准确性的研究,要求至少10例成人患者并以MRI为参考标准。
  • 共纳入8项研究、267例年龄25-54岁的急性膝关节损伤患者,均接受DECT和MRI检查。
  • 由两名评价者独立提取研究资料,采用双变量混合效应回归模型进行Meta分析,并进行亚组分析评估变异来源。
  • 采用QUADAS-2工具评估偏倚风险。

诊断标准与关键数值

  • DECT检测骨髓水肿的汇总敏感度为84%(95%CI 74-91%)。
  • DECT检测骨髓水肿的汇总特异度为96%(95%CI 93-98%)。
  • DECT检测骨髓水肿的汇总AUROC为0.97(95%CI 0.95-0.98)。
  • 基于骨的特征描述特异度低于基于区域的描述:83%(57-95%)vs 97%(96-98%),p<0.05;两者敏感度无差异。

临床应用与阅片要点

  • 作者认为DECT可作为MRI的替代方法用于检测成人急性膝关节损伤的骨髓水肿,尤其当MRI禁忌或不可用时。
  • 采用基于区域的描述方式可能提高特异度(基于区域97% vs 基于骨83%,p<0.05),敏感度无差异。

局限性

  • 未发现其他亚组间统计学差异以解释研究间 presumed 变异。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This systematic review and meta-analysis evaluated the diagnostic accuracy of dual-energy CT (DECT) for detecting bone marrow edema (BME) in adult patients with acute knee injuries.

METHODS: A systematic review of MEDLINE, EMBASE, Scopus, the Cochrane Library, and gray literature was performed from inception to January 31, 2020, using PRISMA-DTA guidelines. The review included studies assessing the diagnostic accuracy of DECT for detecting BME in at least 10 adult patients with acute knee injuries and with an MRI reference standard. Study details were independently extracted by two reviewers. Meta-analysis was performed using a bivariate mixed-effects regression model with subgroup analysis performed to evaluate for sources of variability. Risk of bias (ROB) was evaluated using the QUADAS-2 tool.

RESULTS: Eight studies evaluating 267 patients between the ages of 25-54 with acute knee injuries undergoing DECT and MRI were included in analysis. Summary sensitivity, specificity, and AUROC values for BME were 84% (95% confidence interval (CI) 74-91%), 96% (95% CI 93-98%), and 0.97 (95% CI 0.95-0.98), respectively. Bone-based characterization was found to have lower specificity than region-based characterization (83% (57-95%) versus 97 (96-98%), p < 0.05), but no difference in sensitivity. No other statistical differences were identified amongst study subgroups to account for presumed variability amongst studies. Most studies were rated low risk for bias and applicability concerns.

CONCLUSION: DECT is specific and accurate for detecting BME in adult patients with acute knee injuries and can be used as an alternative to MRI, particularly when MRI is contraindicated or unavailable.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Wilson MP, Lui K, Nobbee D, et al. Diagnostic accuracy of dual-energy CT for detecting bone marrow edema in patients with acute knee injuries: a systematic review and meta-analysis. Skeletal Radiol. 2020. PMID: 33090251. doi:10.1007/s00256-020-03646-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。