FABS MRI序列在远端肱二头肌病变评估中的效用
对46例肘部MRI进行盲法阅片,比较无FABS序列(-F)与有FABS序列(+F)两种条件下对远端肱二头肌腱的评估,两名独立阅片者采用0-3级评分和0-10置信度。合并阅片者内信度为0.800(0.714,0.886),合并平均置信度-F组7.163(1.252) vs +F组8.370(1.264)(p < 0.001)。与手术参考标准(12例)相比,合并诊断准确率-F组0.651(0.420,0.882) vs +F组0.615(0.456,0.875)。FABS序列在少数病例中改变了放射科医生对远端肱二头肌腱的印象,未显著改变诊断准确率,作者不推荐在多数病例中使用;在高分级部分撕裂与完全撕裂的困难病例中,FABS可能有助于识别细微残留肌腱纤维。
要点
- FABS序列仅在少数病例中改变放射科医生对远端肱二头肌腱的评估印象。
- 加用FABS序列后诊断准确率未显著改变:-F组0.651 vs +F组0.615。
- 作者不推荐在多数病例中使用FABS序列,仅高分级部分撕裂与完全撕裂的困难病例可能有助于识别细微残留肌腱纤维。
核心结论
- FABS序列在少数病例中改变了放射科医生对远端肱二头肌腱的印象,且未显著改变诊断准确率。
- 作者不推荐在多数病例中使用FABS序列;在高分级部分撕裂与完全撕裂的困难病例中,FABS可能有助于识别细微残留肌腱纤维。
研究设计与样本
- 对46例肘部MRI进行盲法阅片,由两名独立阅片者分别在不提供FABS序列(-F)和提供FABS序列(+F)的条件下评估远端肱二头肌腱。
- 每例采用0-3级评分对肱二头肌腱分级,并赋予0-10的置信度。
- 以手术结果为参考标准(12例)进行对比。
关键影像表现/征象
- FABS序列在少数病例中改变了放射科医生对远端肱二头肌腱的评估印象。
- 在高分级部分撕裂与完全撕裂的困难病例中,FABS可能有助于识别细微残留肌腱纤维。
诊断标准与关键数值
- 肱二头肌腱采用0-3级评分分级,置信度采用0-10分。
- 与手术参考标准相比,合并诊断准确率-F组0.651(0.420,0.882) vs +F组0.615(0.456,0.875)。
- 合并平均置信度-F组7.163(1.252) vs +F组8.370(1.264),p < 0.001。
- 合并阅片者内信度-F组与+F组之间为0.800(0.714,0.886)。
临床应用与阅片要点
- 作者不推荐在多数病例中使用FABS序列。
- 在高分级部分撕裂与完全撕裂的困难病例中,FABS可能有助于识别细微残留肌腱纤维。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The flexed elbow, abducted shoulder, forearm supinated (FABS) position has been described as a method of imaging the distal biceps tendon on its long axis. The purpose of this study is to evaluate whether obtaining additional MR imaging in the FABS position changes the radiologist's assessment of the distal biceps tendon compared with traditional sequences only.
MATERIALS AND METHODS: Blinded review of 46 elbow MRIs when viewed without (-F) and with (+F) FABS sequences available was performed by two independent readers. The biceps tendon was graded in each case using a 0-3 scale, and a confidence level of 0-10 was assigned. -F and +F reads were compared. Reads were also compared with the surgical reference standard when available, 12 patients.
RESULTS: Pooled intra rater reliability was 0.800 (0.714, 0.886) between the -F and +F groups. Pooled mean confidence was 7.163 (1.252) for the -F group and 8.370 (1.264) for the +F group (p < 0.001). Pooled diagnostic accuracy was 0.651 (0.420, 0.882) for the -F group and 0.615 (0.456, 0.875) for the +F group compared with the surgical reference standard.
CONCLUSION: The FABS sequence changed the radiologist's impression of the distal biceps tendon in the minority of cases and did not significantly change diagnostic accuracy. We do not recommend its use in the majority of cases. In challenging cases of high-grade partial vs complete tendon tear, FABS may be helpful to identify subtle residual tendon fibers.