文献速递骨肌MR

基于MRI测量的股骨干-髌腱角有效性与信度评估

Assessment of validity and reliability of femoral shaft-patellar tendon angle measured on MRI.
PubMed 文献 · Skeletal Radiol · 2020-10-07

横断面研究纳入20例髌股关节不稳(PFI)与20例无PFI受试者,在常规膝关节MRI上测量股骨干与髌腱夹角(FSPT角),由三名评估者完成。FSPT角在PFI组显著高于非PFI组(p < 0.001),组内及组间信度均较高,ROC曲线AUC为0.86(95% CI = 0.74-0.97)。

要点

  • FSPT角在PFI组显著高于非PFI组(p < 0.001)。
  • FSPT角组间信度非PFI组0.82(95% CI = 0.67-0.92),PFI组0.89(95% CI = 0.78-0.95)。
  • FSPT角区分PFI与非PFI的ROC曲线AUC为0.86(95% CI = 0.74-0.97)。

核心结论

  • MRI测量的FSPT角具有较高的组内和组间信度,在PFI组显著高于非PFI组,并在ROC曲线中显示出良好的区分两组的能力。

研究设计与样本

  • 横断面研究,纳入20例PFI受试者与20例无PFI受试者,获取膝关节MRI,由三名不同评估者测量FSPT角,并在对照组测量临床Q角。

关键影像表现/征象

  • 在常规膝关节MRI上测量股骨干与髌腱之间的夹角(FSPT角),用以代表股四头肌机制的侧向矢量力。

诊断标准与关键数值

  • FSPT角在PFI组显著高于非PFI组(p < 0.001)。
  • FSPT角组间信度:非PFI组0.82(95% CI = 0.67-0.92),PFI组0.89(95% CI = 0.78-0.95)。
  • FSPT角重测信度大于0.90。
  • FSPT角区分PFI与非PFI的ROC曲线AUC为0.86(95% CI = 0.74-0.97)。
  • 非PFI受试者临床Q角组间信度仅0.48(95% CI = 0.21-0.72),与MRI角度呈0.58的fair相关。

临床应用与阅片要点

  • 作者在研究中描述了在MRI上测量股骨干-髌腱角(FSPT角)的方法,用于代表股四头肌机制的侧向矢量力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: Clinically measured Quadriceps angle (Q-angle) has low reliability. Measurement of angle between femoral shaft and patellar tendon (FSPT angle) on routine knee MRI was described in this study to represent the lateral vector forces of quadriceps mechanism. The cross-sectional study was designed to compare this angle between subjects with objective patellofemoral instability (PFI) versus those without PFI, to assess its reliability, and to assess its validity in terms of its ability to differentiate between PFI and non-PFI subjects using the "Receiver Operating Characteristic" (ROC) curve.

MATERIALS AND METHODS: MRI scans of 20 subjects with PFI and 20 without PFI were obtained. FSPT angle was measured in each MRI by three different raters. In addition, the clinical Q-angle was also measured in the control group.

RESULTS: The FSPT angle was significantly higher in PFI group as compared with the non-PFI group (p < 0.001). It had substantial inter-rater reliability of 0.82 (95% CI = 0.67-0.92) in the non-PFI group and 0.89 (95% CI = 0.78-0.95) in the PFI group. Test-retest reliability was more than 0.90. The AUC for the ROC curve was 0.86 (95% CI = 0.74-0.97). The clinical Q-angle measured in non-PFI subjects had inter-rater reliability of only 0.48 (95% CI = 0.21-0.72), and showed a fair correlation of 0.58 with the MRI angle.

CONCLUSION: Measurement of FSPT angle was described on MRI with substantial intra-rater and inter-rater reliability. The angle was significantly higher in PFI versus non-PFI subjects and also showed a good ability to differentiate between these two groups in the ROC curve.