超声引导与盲法注射在髌腱病变中的对比:一项尸体研究
该尸体随机研究比较了超声引导与非超声引导(盲法)注射在髌腱病变中命中髌腱近端背侧「靶点」的准确性。26 具新鲜尸体的 26 个膝关节由 26 名有肌肉骨骼超声和注射治疗经验的从业者进行注射,每人完成 6 次超声引导和 6 次盲法穿刺,共 312 次注射,在 2 个不同解剖切面分析,获得 624 个测量值。结果显示超声引导注射准确率为 74.36%,盲法注射为 11.54%(p < 0.0001),盲法注射平均偏离靶点约 10 mm,差异有统计学意义。
要点
- 超声引导注射命中髌腱近端背侧靶点的准确率为 74.36%,盲法注射为 11.54%。
- 盲法注射平均偏离靶点约 10 mm,与超声引导注射的偏差差异有统计学意义(p < 0.0001)。
- 在尸体标本上,超声引导可显著提高髌腱病变注射定位的准确性。
诊断标准与关键数值
- 超声引导注射命中靶点的准确率为 74.36%,非超声引导(盲法)注射的准确率为 11.54%(p < 0.0001)。
- 盲法注射平均偏离靶点约 10 mm,与超声引导注射相比差异有统计学意义(p < 0.0001)。
临床应用与阅片要点
- 作者认为,超声引导下将注射定位于髌腱近端背侧可显著提高准确性,该发现对注射治疗具有重要价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The present study aims to analyze the accuracy of injections aimed to hit the proximal and depth part of the patellar tendon "target point" in patellar tendinopathy, comparing ultrasound-guided or non-ultrasound-guided (blind) injections.
METHODS: A cadaver randomized study was carried out. Injections were performed under ultrasound control, as well as blinded. There were 26 knees from fresh cadavers and injections were placed by 26 practitioners with experience in the use of musculoskeletal ultrasound and injection treatment. Each participant performed 6 ultrasound-guided and 6 blind punctures in different cadaveric specimens. This provided 312 injections that were analyzed in 2 different anatomical cuts, thus providing a database of 624 measurements for statistical analysis.
RESULTS: Statistically significant differences were observed (p < 0.0001) in the distance from the target point between the ultrasound-guided and the non-guided infiltrations. The "unguided" injections were considered to have been performed on average 10 mm away from the target point compared to the "ultrasound-guided" injections. The ultrasound-guided injections obtained an accuracy of 74.36% while the "non-ultrasound-guided" injections obtained an accuracy of 11.54% (p < 0.0001).
CONCLUSION: The use of ultrasound to guide the positioning of injections on the dorsal side of the proximal patellar tendon had a significantly higher accuracy compared to blind injections. The finding provides knowledge of importance for injection treatment.
引用
- Abat F, Alfredson H, Campos J, et al. Ultrasound-guided versus blind interventions in patellar tendon lesions: a cadaveric study. Skeletal Radiol. 2020. PMID: 33063137. doi:10.1007/s00256-020-03635-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。