股骨软骨超声回声强度与关节镜下软骨损伤相关
本研究比较前交叉韧带损伤后伴有关节镜下软骨损伤者(12例)与无损伤者(12例)的定量软骨超声指标。结果显示,内侧股骨软骨回声强度均值和异质性每降低1个标准差,关节镜下软骨损伤的比值分别增加91%和97%;外侧软骨超声指标与外侧关节镜下软骨损伤无关。
要点
- 内侧股骨软骨回声强度降低与关节镜下软骨损伤风险增加相关。
- 外侧股骨软骨超声指标与外侧关节镜下软骨损伤无关联。
- 超声回声强度可能作为评估前交叉韧带损伤后股骨软骨健康的无创指标。
核心结论
- 股骨软骨超声回声强度是一种与前交叉韧带损伤后内侧股骨软骨健康相关的无创测量指标,提供初步证据。
研究设计与样本
- 比较性研究,纳入前交叉韧带损伤后伴关节镜下软骨损伤者12例与无损伤者12例(年龄24.9±3.7岁;女性33%,男性67%;伤后50±52天),在临床关节镜术前对损伤侧膝关节行股骨软骨横断面髌上超声评估,由骨科医生采用Outerbridge分级系统评估关节镜下软骨损伤(软骨损伤定义为Outerbridge≥1)。
诊断标准与关键数值
- 关节镜下软骨损伤定义为Outerbridge分级≥1。
- 内侧股骨软骨回声强度均值每降低1个标准差,关节镜下软骨损伤的校正比值比为0.09(95%CI 0.01-0.69),即 odds 增加91%。
- 内侧股骨软骨回声强度异质性每降低1个标准差,关节镜下软骨损伤的校正比值比为0.03(95%CI 0.002-0.50),即 odds 增加97%。
- 外侧股骨软骨超声指标与外侧关节镜下软骨损伤无关联。
临床应用与阅片要点
- 作者认为股骨软骨超声回声强度是前交叉韧带损伤后内侧股骨软骨健康的无创测量指标(初步证据)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
This study compared quantitative cartilage ultrasound metrics between people with (n = 12) and without (n = 12) arthroscopic cartilage damage after anterior cruciate ligament injury (age, 24.9 ± 3.7 y; sex, 33% female, 67% male; days since injury = 50 ± 52). A transverse suprapatellar ultrasound assessment imaged the femoral cartilage in participants' injured knees before a clinical arthroscopy. A custom program automatically separated a manual cartilage segmentation into standardized medial and lateral femoral regions and calculated mean thickness (i.e., cross-sectional area/length of cartilage-bone interface), mean echo intensity and echo-intensity heterogeneity. An orthopedic surgeon assessed arthroscopic cartilage damage in the medial and lateral femoral condyles using the Outerbridge grading system (cartilage damage = Outerbridge ≥ 1). Separate logistic regressions for medial and lateral femoral cartilage were used to determine the association between each ultrasound metric and arthroscopic cartilage damage. In medial femoral cartilage, for every 1 standard deviation decrease in echo-intensity mean and heterogeneity, there is, respectively, a 91% (adjusted odds ratio, 0.09; 95% confidence interval, 0.01-0.69) and 97% (adjusted odds ratio, 0.03; 95% confidence interval, 0.002-0.50) increase in the odds of having arthroscopic cartilage damage. Lateral cartilage ultrasound metrics are not associated with lateral arthroscopic cartilage damage. This study provides preliminary evidence that femoral cartilage ultrasound echo intensity is a non-invasive measure associated with medial femoral cartilage health after anterior cruciate ligament injury.
引用
- Harkey MS, Little E, Thompson M, et al. Femoral Cartilage Ultrasound Echo Intensity Associates with Arthroscopic Cartilage Damage. Ultrasound Med Biol. 2020. PMID: 33082054. doi:10.1016/j.ultrasmedbio.2020.09.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。