超声引导下细针穿刺细胞学与甲状腺球蛋白测定对分化型甲状腺癌患者淋巴结转移诊断性能的比较:一项Meta分析
该Meta分析纳入21项研究、2712例分化型甲状腺癌患者的1662枚恶性与1279枚良性淋巴结,比较FNAC、单独FNA-Tg及两者联合的诊断性能。FNAC特异性更高(汇总特异度0.98),FNA-Tg敏感性更高(汇总敏感度0.94);两者联合诊断性能优于任一单独方法(DOR 446.00,AUC 0.9862),术前(DOR 378.14,AUC 0.9879)与术后(DOR 788.72,AUC 0.9930)均如此;FNAC联合FNA-Tg/血清Tg比值较FNAC联合FNA-Tg获得更高特异度(0.98)。
要点
- FNAC特异性高于FNA-Tg(汇总特异度0.98),FNA-Tg敏感性高于FNAC(汇总敏感度0.94)。
- FNAC联合FNA-Tg诊断性能优于任一单独方法,术前DOR 378.14、AUC 0.9879,术后DOR 788.72、AUC 0.9930。
- FNAC联合FNA-Tg/血清Tg比值的特异度(0.98)高于FNAC联合FNA-Tg。
核心结论
- 在FNAC基础上加做FNA-Tg(尤其是FNA-Tg/血清Tg比值)可提高分化型甲状腺癌患者术前和术后淋巴结转移的诊断性能。
- 由于单项检查或联合方案在不同临床情境下表现不同,应据此选择最合适的检查。
研究设计与样本
- 研究类型为Meta分析,按预设标准筛选文献,并按QUADAS-2清单评价文献质量。
- 共纳入21项研究,来自2712例分化型甲状腺癌患者的1662枚恶性淋巴结和1279枚良性淋巴结。
- 计算汇总敏感度、特异度、阳性/阴性似然比及诊断比值比(DOR),并使用Meta-DiSc1.4软件绘制汇总受试者工作特征(SROC)曲线。
诊断标准与关键数值
- FNAC汇总特异度为0.98,FNA-Tg汇总敏感度为0.94。
- FNAC联合FNA-Tg的DOR为446.00、AUC为0.9862;术前DOR为378.14、AUC为0.9879,术后DOR为788.72、AUC为0.9930。
- FNAC联合FNA-Tg/血清Tg比值的特异度为0.98,高于FNAC联合FNA-Tg。
- 术后FNAC及FNAC联合FNA-Tg的诊断表现优于FNA-Tg,而术前FNA-Tg表现更好。
临床应用与阅片要点
- 术前可优先关注FNA-Tg的较高敏感性,术后可优先关注FNAC及FNAC联合FNA-Tg的较好表现。
- 联合FNAC与FNA-Tg(尤其FNA-Tg/血清Tg比值)可提高淋巴结转移诊断性能,但原文未据此给出具体推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Ultrasound (US)-guided fine needle aspiration cytology (FNAC) and thyroglobulin measurement (FNA-Tg) are two common methods for confirming lymph node metastases (LNM) in patients with differentiated thyroid carcinoma (DTC). This study aimed at comparing the diagnostic performance of FNAC, FNA-Tg alone, and in combination by means of a meta-analysis.
METHODS: Eligible articles were selected according to predefined criteria, and their quality was evaluated as per the QUADAS-2 checklist. We calculated pooled sensitivity (Se), specificity (Sp), positive/negative likelihood ratio, and diagnostic odds ratio (DOR), and plotted the summary receiver operating characteristic (SROC) curve using the Meta-DiSc1.4 software.
RESULTS: Twenty-one studies pooling 1662 malignant and 1279 benign LNs from 2712 patients with DTC were included. The results showed that FNAC was more specific (pooled Sp, 0.98) while FNA-Tg was more sensitive (pooled Se, 0.94). FNAC and FNAC+FNA-Tg performed better postoperatively than FNA-Tg, while FNA-Tg performed better preoperatively. The combination of FNAC and FNA-Tg could achieve a better diagnostic performance than each alone (DOR 446.00, area under the curve [AUC] 0.9862), no matter preoperatively (DOR 378.14, AUC 0.9879) or postoperatively (DOR 788.72, AUC 0.9930). Besides, the combination of FNAC and FNA-Tg/serum-Tg ratio obtained a higher Sp (0.98) than the combination of FNAC and FNA-Tg.
CONCLUSION: The addition of FNA-Tg, especially the FNA-Tg/serum-Tg ratio, to FNAC could increase the diagnostic performance of LNM in both preoperative and postoperative patients with DTC. Since one test or test combinations could perform differently according to the clinical situation, the best-fitting test should be chosen accordingly.
KEY POINTS: • FNAC is more specific than FNA-Tg while FNA-Tg is more sensitive than FNAC. • The combination of FNAC and FNA-Tg could achieve a better diagnostic performance than either alone, no matter preoperatively or postoperatively. • The combination of FNAC and FNA-Tg/serum-Tg ratio could reach a higher Sp than the combination of FNAC and FNA-Tg.
引用
- Liu RB, Zhou DL, Xu BH, et al. Comparison of the diagnostic performances of US-guided fine needle aspiration cytology and thyroglobulin measurement for lymph node metastases in patients with differentiated thyroid carcinoma: a meta-analysis. Eur Radiol. 2020. PMID: 33125564. doi:10.1007/s00330-020-07400-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。