文献速递甲状腺与浅表介入US

水分离技术与程序化停止镇静用于全部良性甲状腺结节射频消融治疗

Hydrodissection and programmed stop sedation in 100 % of benign thyroid nodules treated with radiofrequency ablation.
PubMed 文献 · Eur J Radiol · 2020-10-16

双中心回顾性研究纳入34例患者共52个症状性良性甲状腺结节,均行超声引导下射频消融,术前常规以5%葡萄糖溶液水分离并采用程序化停止的清醒镇静。消融后1、3、6、12个月体积缩小率分别为46.6%、64.5%、76.1%、88.8%,无手术相关并发症,常规水分离和程序化停止镇静使总消融时间增加不超过5分钟。

要点

  • 消融后12个月结节体积缩小率达88.8%,1、3、6个月分别为46.6%、64.5%、76.1%。
  • 全部患者术前接受5%葡萄糖溶液水分离,术中采用程序化停止的清醒镇静。
  • 无严格与操作相关的并发症,水分离和镇静使总消融时间增加不超过5分钟。

关键影像表现/征象

  • 结节以实性或几乎完全实性为主(n=45,占88.3%),囊性成分n=4(7.8%),混合性n=2(3.9%)。
  • 位置以右叶为主(n=29,56.9%),左叶n=17(33.3%),峡部n=5(9.8%)。
  • 消融前结节平均体积为18.2±20.5 mL。
  • 消融后1、3、6、12个月体积缩小率分别为46.6%、64.5%、76.1%、88.8%。
  • 未报告严格与操作相关的并发症。

临床应用与阅片要点

  • 作者经验认为,5%葡萄糖溶液水分离、清醒镇静及术中程序化停止刺激可在所有患者中常规开展,可能提高操作安全性。
  • 常规水分离和程序化停止镇静使总消融时间增加不超过5分钟。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To describe our group experience in treatment of benign symptomatic thyroid nodules using radiofrequency ablation technique always associated to routine pre-procedure hydrodissection and under sedation with programmed stop.

METHODS: Dual-center, retrospective study conducted between April 2018 and January 2020. A total of 52 symptomatic benign thyroid nodules were treated in 34 patients with ultrasound-guided percutaneous radiofrequency ablation. The technique of choice was moving-shot technique and 100 % patients underwent pre-procedural hydrodissection with 5% glucose solution, plus conscious sedation with programmed stop during procedure.

RESULTS: Most nodules were solid or almost completely solid (n = 45, 88.3 % of nodules), followed by cystic composition (n = 4, 7.8 %) and mixed (n = 2, 3.9 %). As for location, most were on the right lobe (n = 29, 56.9 %), followed by the left lobe (n = 17, 33.3 %) and isthmus (n = 5, 9.8 %). The average volume of nodules before ablation was 18.2 ± 20.5 mL. Volumetric reduction rates at one, three, six and twelve months after ablation were 46.6 %, 64.5 %, 76.1 % and 88.8 %, respectively. No complications strictly related to procedure were reported. No more than 5 min were added to total time of ablative treatment considering routine hydrodissection and stop programmed sedation.

CONCLUSIONS: Minimally invasive therapies applied to thyroid allow the preservation of healthy thyroid parenchyma and provide a very effective volumetric reduction of symptomatic benign thyroid nodules. Hydrodissection with 5 % glucose solution, conscious sedation and patient stimulation with programmed stop during procedure may provide greater safety to procedure, and, in our experience, could be done routinely in all patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Souza KP, Rahal A, Volpi EM, et al. Hydrodissection and programmed stop sedation in 100 % of benign thyroid nodules treated with radiofrequency ablation. Eur J Radiol. 2020. PMID: 33099221. doi:10.1016/j.ejrad.2020.109354

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。