比较简化乳腺MRI与全诊断方案MRI在乳腺癌中诊断性能的Meta分析
该Meta分析比较简化乳腺MRI(ABB-MRI)与全诊断方案MRI(FDP-MRI)的诊断性能,纳入5项筛查人群研究和8项富集队列研究。筛查研究中ABB-MRI与FDP-MRI的汇总敏感度/特异度/AUC分别为0.90/0.92/0.94与0.92/0.95/0.97;富集队列中分别为0.93/0.83/0.94与0.93/0.84/0.95,两者敏感度与特异度均无显著差异。作者结论为两种方案诊断性能相当。
要点
- 筛查人群中ABB-MRI汇总敏感度0.90、特异度0.92、AUC 0.94,FDP-MRI分别为0.92、0.95、0.97。
- 富集队列中ABB-MRI汇总敏感度0.93、特异度0.83、AUC 0.94,FDP-MRI分别为0.93、0.84、0.95。
- ABB-MRI与FDP-MRI的敏感度和特异度均无显著差异(筛查组p=0.18和0.27,富集组p=0.18和0.93)。
诊断标准与关键数值
- 筛查研究:ABB-MRI汇总敏感度0.90、特异度0.92、AUC 0.94;FDP-MRI汇总敏感度0.92、特异度0.95、AUC 0.97。
- 富集队列研究:ABB-MRI汇总敏感度0.93、特异度0.83、AUC 0.94;FDP-MRI汇总敏感度0.93、特异度0.84、AUC 0.95。
- ABB-MRI与FDP-MRI敏感度比较:筛查组p=0.18,富集组p=0.18;特异度比较:筛查组p=0.27,富集组p=0.93。
临床应用与阅片要点
- 作者结论认为,用于筛查或富集队列时,ABB-MRI与FDP-MRI方案的诊断性能相当。
局限性
- 患者人群、研究方法和所报告的简化方案存在较大变异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To undertake a meta-analysis of the diagnostic performance of abbreviated (ABB) magnetic resonance imaging (MRI) and full diagnostic protocol MRI (FDP-MRI) in breast cancer.
MATERIALS AND METHODS: This meta-analysis was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis for Diagnostic Test Accuracy (PRISMA-DTA) guidelines. The PubMed and EMBASE databases were searched through August 2019 for studies comparing the diagnostic performance of ABB-MRI and FDP-MRI in the breast. Studies were reviewed by two authors independently according to eligibility and exclusion criteria and split into two subgroups (screening population studies and studies using cohorts enriched with known cancers) to avoid bias. Quality assessment and bias for diagnostic accuracy was determined with Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). The diagnostic accuracy for each subgroup was pooled using a bivariate random effects model and summary receiver operating characteristic (sROC) curves produced. Sensitivities and specificities were compared using a paired t-test.
RESULTS: Five screening (62/2,588 cancers/patients) and eight enriched cohort (540/1,432 cancers/patients) studies were included in the meta-analysis. QUADAS-2 assessment showed a low risk of bias in most studies. The pooled sensitivity/specificity/area under the receiver operating characteristic curve (AUC) for screening studies was 0.90/0.92/0.94 for ABB-MRI and 0.92/0.95/0.97 for FDP-MRI. The pooled sensitivity/specificity/AUC for enriched cohort studies was 0.93/0.83/0.94 for ABB-MRI and 0.93/0.84/0.95 for FDP-MRI. There was no significant difference in sensitivity or specificity using ABB-MRI or FDP-MRI (p=0.18 and 0.27, p=0.18 and 0.93, respectively).
CONCLUSION: The diagnostic performances of the ABB-MRI and FDP-MRI protocols used in either screening or enriched cohorts were comparable. There was a large variation in patient population, study methodology, and abbreviated protocols reported.
引用
- Baxter GC, Kaya A, Mackay JW, et al. A meta-analysis comparing the diagnostic performance of abbreviated MRI and a full diagnostic protocol in breast cancer. Clin Radiol. 2020. PMID: 33032820. doi:10.1016/j.crad.2020.08.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。