文献速递乳腺乳腺X线

数字乳腺断层摄影联合合成乳腺摄影与数字乳腺摄影乳腺癌筛查的多中心评估

Multicenter Evaluation of Breast Cancer Screening with Digital Breast Tomosynthesis in Combination with Synthetic versus Digital Mammography.
PubMed 文献 · Radiology · 2020-10-13

该回顾性多中心研究比较了合成乳腺摄影联合数字乳腺断层摄影(SM/DBT)与数字乳腺摄影联合数字乳腺断层摄影(DM/DBT)的筛查结局。纳入151363例筛查 Examination,SM/DBT未调整召回率低于DM/DBT(7.0% vs 7.9%,P < .01),但多变量调整后SM/DBT召回率略高(调整OR 1.06,95%CI 1.01-1.11,P = .02)、特异度略低(调整OR 0.95,95%CI 0.90-0.99,P = .02)。活检率、假阴性率、癌症检出率、阳性预测值和敏感度均无统计学显著差异。结论认为SM替代DM联合DBT筛查时性能维持在基准范围内。

要点

  • SM/DBT未调整召回率7.0%低于DM/DBT的7.9%(P < .01),但多变量调整后SM/DBT召回率略高(调整OR 1.06,P = .02)。
  • 多变量调整后SM/DBT特异度略低于DM/DBT(调整OR 0.95,95%CI 0.90-0.99,P = .02)。
  • 活检率、假阴性率、癌症检出率、阳性预测值和敏感度在SM/DBT与DM/DBT间均无统计学显著差异。

核心结论

  • 在数字乳腺断层摄影联合合成乳腺摄影替代数字乳腺摄影后,乳腺癌筛查性能维持在基准范围内。

研究设计与样本

  • 回顾性研究,纳入两家机构连续筛查乳腺摄影检查,共151363例(平均年龄58.1岁±10.9)。
  • 宾夕法尼亚大学:2011年10月3日至2014年10月31日DM/DBT 34106例,2015年1月7日至2018年2月2日SM/DBT 34180例。
  • 佛蒙特大学:2012年1月1日至2016年5月31日DM/DBT 51148例,2016年6月1日至2018年3月30日SM/DBT 31929例。
  • 计算召回率、活检率、假阴性率、癌症检出率、阳性预测值、敏感度和特异度,采用描述性统计、χ2检验和逻辑回归分析。

诊断标准与关键数值

  • SM/DBT未调整召回率7.0%(4630/66109)vs DM/DBT 7.9%(6742/85254),P < .01。
  • 多变量调整后SM/DBT召回率较DM/DBT略高:调整OR 1.06(95%CI 1.01-1.11),P = .02。
  • 多变量调整后SM/DBT特异度较DM/DBT略低:调整OR 0.95(95%CI 0.90-0.99),P = .02。
  • 活检率(P = .54)、假阴性率(P = .38)、癌症检出率(P = .55)、浸润性癌检出率(P = .52)、原位癌检出率(P = .98)、阳性预测值(P = .78)、敏感度(P = .33)在SM/DBT与DM/DBT间总体及两机构内均无统计学显著差异(P > .05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BackgroundDigital breast tomosynthesis (DBT) combined with digital mammography (DM) is increasingly used in the United States instead of DM alone for breast cancer screening. Early screening outcomes incorporating synthetic mammography (SM) with DBT have suggested that SM is an acceptable non-radiation dose alternative to DM.PurposeTo compare multicenter outcomes from breast cancer screening with SM/DBT versus DM/DBT.Materials and MethodsThis was a retrospective study of consecutive screening mammograms obtained at two institutions. Eligible studies consisted of 34 106 DM/DBT examinations between October 3, 2011, and October 31, 2014, and 34 180 SM/DBT examinations between January 7, 2015, and February 2, 2018, at the University of Pennsylvania and 51 148 DM/DBT examinations between January 1, 2012, and May 31, 2016, and 31 929 SM/DBT examinations between June 1, 2016, and March 30, 2018, at the University of Vermont. Demographics of women who attended screening and results from screening were recorded. Recall rate, biopsy rate, false-negative rate, cancer detection rate, positive predictive value, sensitivity, and specificity were calculated according to modality and institution. Descriptive statistics, χ2 tests, and logistic regression were used in analysis.ResultsThe study included 151 363 screening examinations among 151 363 women (mean age, 58.1 years ± 10.9 [standard deviation]). The unadjusted recall rate was lower with SM/DBT than with DM/DBT (7.0% [4630 of 66 109 examinations] for SM/DBT vs 7.9% [6742 of 85 254 examinations] for DM/DBT; P < .01). However, after multivariable adjustment, SM/DBT was associated with a slightly higher recall rate compared with DM/DBT (adjusted odds ratio [OR], 1.06; adjusted 95% CI: 1.01, 1.11; P = .02). Similarly, after multivariable adjustment, SM/DBT was associated with slightly lower specificity compared with DM/DBT (adjusted OR, 0.95; adjusted 95% CI: 0.90, 0.99; P = .02). There was no statistically significant difference in biopsy rate (P = .54), false-negative rate (P = .38), cancer detection rate (P = .55), invasive or in situ cancer detection rate (P = .52 and P = .98, respectively), positive predictive value (P = .78), or sensitivity (P = .33) for SM/DBT versus DM/DBT overall or within either institution (P > .05 for all).ConclusionBreast cancer screening performance is maintained within benchmarks when synthetic mammography replaces digital mammography in digital breast tomosynthesis imaging.© RSNA, 2020Online supplemental material is available for this article.See also the editorial by Lång in this issue.

来源:Radiology,查看原文。版权归原作者所有。