基于乳腺磁共振成像检出病灶的多参数分类系统
研究纳入499例受试者的697个病灶,依据BI-RADS MRI词典描述词、ADC、T2加权信号强度及动力学曲线评估分类,将描述词分为次要、中等、主要发现并按数量归入BI-RADS 3、4A、4B、4C、5类。各BI-RADS类别恶性阳性预测值依次为4A 11.1%、4B 28.3%、4C 64.4%、5 94.8%,BI-RADS 3类无一例恶性,作者认为该多参数分类系统可得出阳性预测值处于BI-RADS推荐范围内的病灶分类。
要点
- BI-RADS 3类病灶无一例恶性,4A、4B、4C、5类恶性阳性预测值分别为11.1%、28.3%、64.4%、94.8%。
- MRI描述词的阳性预测值范围为17.9%–100%。
- 所有描述词组在多因素logistic回归模型中均有统计学意义。
核心结论
- 作者认为,将BI-RADS MRI描述词与ADC、T2加权信号强度结合用于多参数分类系统,可得出阳性预测值处于BI-RADS各类别推荐范围内的病灶分类。
研究设计与样本
- 研究分析了499例受试者中检出的697个病灶的MRI描述词与ADC。
- 描述词分为次要、中等、主要发现,并按描述词数量归入BI-RADS 3、4A、4B、4C、5亚类。
- 计算每个描述词的阳性预测值,并将描述词纳入多项logistic回归模型以确定恶性诊断的比值比。
- 测量新分类的阳性预测值,并与BI-RADS描述词所赋阳性预测值比较。
关键影像表现/征象
- MRI描述词的阳性预测值范围为17.9%–100%。
- 697个病灶中,19个(2.7%)归为BI-RADS 3类,27个(3.9%)为4A类,53个(7.6%)为4B类,174个(25.0%)为4C类,424个(60.8%)为5类。
- BI-RADS 3类受试者中无一例恶性诊断。
诊断标准与关键数值
- 恶性阳性预测值随BI-RADS类别升高而递增:4A类11.1%、4B类28.3%、4C类64.4%、5类94.8%。
- 所有描述词组在logistic回归模型中均有统计学意义。
临床应用与阅片要点
- 阅片时可依据BI-RADS MRI描述词数量并结合ADC与T2加权信号强度,将病灶归入BI-RADS 3至5类以对应恶性阳性预测值。
- BI-RADS 3类在本研究697个病灶中无一例恶性,4A类阳性预测值为11.1%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: To validate a new categorisation scheme for suspicious breast lesions according to the well-defined Breast Imaging Reporting and Data System (BI-RADS) magnetic resonance imaging (MRI) lexicon descriptors, apparent diffusion coefficients (ADC), T2-weighted signal intensity (SI), and kinetic curve assessment categories.
METHODS: The MRI descriptors and ADC were analysed in 697 lesions detected in 499 subjects. The descriptors were classified into Minor, Intermediate, and Major findings, and were divided into the BI-RADS subcategories 3, 4A, 4B, 4C, and 5 according to the number of descriptors. Positive predictive values (PPV) were calculated for each descriptor. The descriptors were then fitted into a multinomial logistic regression model to determine the odds ratio for a malignant diagnosis. The PPV were measured for the new categories and compared with the assigned PPV of the BI-RADS descriptors.
RESULTS: The PPV for MRI descriptors ranged from 17.9%-100%. Of the 697 lesions assessed, 19 (2.7 %) were categorized as BI-RADS 3, 27 (3.9 %) as 4A, 53 (7.6 %) as 4B, 174 (25.0 %) as 4C, and 424 (60.8 %) as 5. None of the subjects in BI-RADS category 3 had a malignant diagnosis. The PPV for malignancy increased progressively with increasing BI-RADS category (4A, 11.1 %; 4B, 28.3 %; 4C, 64.4 %; 5, 94.8 %). All descriptor groups were significant in the logistic regression model.
CONCLUSIONS: This study shows that using BI-RADS MRI descriptors together with ADC and T2-weighted SI in a multiparametric classification system can yield an applicable categorisation of lesions with PPV values within the recommended ranges for BI-RADS categories.
引用
- Istomin A, Masarwah A, Okuma H, et al. A multiparametric classification system for lesions detected by breast magnetic resonance imaging. Eur J Radiol. 2020. PMID: 33045483. doi:10.1016/j.ejrad.2020.109322
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。