从脐动脉多普勒波形测定胎儿心率短期变异

Determination of fetal heart rate short-term variation from umbilical artery Doppler waveforms.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-12-03

这项前瞻性纵向研究在两家研究中心纳入195例低危妊娠,于14至40周孕龄每4周行脐动脉脉冲波多普勒检查,用离线软件分析最多12个连续波形并以平均R-R间期计算基线校正的胎儿心率短期变异。短期变异随孕龄显著增加,且与心率呈负相关;作者指出该方法可行且稳健,但所测短期变异与计算机胎心监护所得不可互换,尚需进一步研究验证其与结局的关联。

要点

  • 脐动脉多普勒波形可提取胎儿心率短期变异,随孕龄增加:14-20周中位数3.5 ms,34-40周6.3 ms。
  • 基线校正的胎儿心率短期变异与心率呈负相关(条件R²=0.54,P<0.0001)。
  • 脐动脉多普勒所得短期变异与计算机胎心监护测值不可互换,不能直接套用后者判读标准。

核心结论

  • 脐动脉多普勒波形是获取胎儿心率短期变异的一种稳健且可行的方法。
  • 脐动脉多普勒来源的短期变异与计算机胎心监护测值不可互换,需进一步研究验证其与结局的关联,以确定该技术同时评估胎儿心血管与心率的价值。

研究设计与样本

  • 前瞻性纵向研究,在两家研究中心纳入195例低危妊娠。
  • 于14至40周孕龄每4周行脐动脉脉冲波多普勒检查,采用标准化成像方案。
  • 用离线处理软件分析最多12个连续脐动脉多普勒波形,以提取的平均R-R间期计算胎儿心率短期变异,并对心率做基线校正。

诊断标准与关键数值

  • 基线校正的胎儿心率短期变异随孕龄显著增加(条件R²=0.37,P<0.0001)。
  • 基线校正的胎儿心率短期变异与心率呈负相关(条件R²=0.54,P<0.0001)。
  • 短期变异中位数(四分位间距)由14-20周的3.5(2.9-4.1)ms升至34-40周的6.3(4.8-7.7)ms。
  • 心率短期变异的变化在不同研究中心或不同超声医师之间无差异。

临床应用与阅片要点

  • 作者指出脐动脉多普勒来源的短期变异与计算机胎心监护测值不可互换,报告中不应直接套用后者的判读标准。
  • 作者认为需进一步研究验证该短期变异与结局的关联,以确定该技术同时评估胎儿心血管与心率的价值。

局限性

  • 作者指出脐动脉多普勒来源的短期变异与计算机胎心监护测值不可互换。
  • 作者指出需进一步研究验证该短期变异与结局的关联,以确定该技术的价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the feasibility of using umbilical artery (UA) Doppler waveforms to measure fetal heart rate (FHR) short-term variation (STV) across gestation.

METHODS: This was a prospective longitudinal study, conducted at two study sites, of 195 pregnancies considered low risk. Pulsed-wave Doppler of the UAs was performed at 4-weekly intervals, between 14 and 40 weeks of gestation, using a standardized imaging protocol. Up to 12 consecutive UA Doppler waveforms were analyzed using offline processing software. FHR STV was calculated using average R-R intervals extracted from the waveforms and baseline corrected for FHR.

RESULTS: Baseline-corrected FHR STV increased significantly with gestational age (conditional R2 = 0.37; P < 0.0001) and was correlated inversely with FHR (conditional R2 = 0.54; P < 0.0001). The STV ranged (median (interquartile range)) from 3.5 (2.9-4.1) ms at 14-20 weeks' gestation to 6.3 (4.8-7.7) ms at 34-40 weeks' gestation. The change in heart rate STV did not differ between study sites or individual sonographers.

CONCLUSIONS: UA Doppler waveforms offer a robust and feasible method to derive STV of the FHR. It should be emphasized that the UA Doppler-derived STV is not interchangeable with measurements derived with computerized cardiotocography. Accordingly, further investigations are needed to validate associations with outcome, in order to determine the value of concurrent fetal cardiovascular and heart rate evaluations that are possible with the technique described here. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Cahill LS, Stortz G, Ravi Chandran A, et al. Determination of fetal heart rate short-term variation from umbilical artery Doppler waveforms. Ultrasound Obstet Gynecol. 2020. PMID: 33030756. doi:10.1002/uog.23145

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。