文献速递腹部泌尿生殖技术与安全CT

双能谱CT虚拟平扫替代肾癌真实平扫的可行性研究

Replacing true unenhanced imaging in renal carcinoma with virtual unenhanced images in dual-energy spectral CT: a feasibility study.
PubMed 文献 · Clin Radiol · 2020-09-29

回顾56例经组织病理学证实的肾癌病例,行常规平扫及动脉期、静脉期双能谱CT增强扫描,在工作站生成虚拟平扫(VNC)图像。结果显示VNC图像质量与真实平扫(TNC)无差异,病灶CNR与SNR显著高于TNC、肾脏噪声低于TNC,病灶与肾脏CT值较TNC高但差值<5 HU;结论认为VNC可能替代常规平扫以减少检查时间和辐射剂量。

要点

  • VNC图像主观质量与TNC无差异,两名医师评分一致性良好(Kappa>0.70)。
  • VNC的CNR和SNR显著高于TNC(p<0.05),肾脏噪声显著低于TNC(p<0.05)。
  • VNC病灶与肾脏CT值较TNC高(p<0.05),但差值<5 HU,病灶长、短径三组间无差异。

关键影像表现/征象

  • VNC图像上病灶与肾脏的CT值均高于TNC(p<0.05),但差值<5 HU。
  • VNC图像的CNR和SNR显著高于TNC(p<0.05)。
  • VNC图像的肾脏噪声低于TNC(p<0.05)。
  • 三组图像间病灶长径和短径无差异。
  • 两名阅片者对图像质量主观评分一致性良好(Kappa>0.70),三组图像质量评分无差异,病灶征象评分均高于可接受水平。

诊断标准与关键数值

  • 图像质量采用五分制主观评分,病灶征象采用三分制评分,病灶征象评分均高于可接受水平。
  • 两名阅片者主观评价一致性Kappa>0.70。

临床应用与阅片要点

  • 作者认为双能谱CT的VNC图像可能替代常规平扫,以减少检查时间和辐射剂量。
  • VNC病灶与肾脏CT值较TNC高但差值<5 HU,阅片测值时需注意此微小偏差。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the clinical value of virtual unenhanced (VNC) spectral computed tomography (CT) images to replace the conventional true unenhanced spectral CT images (TNC) in diagnosing renal carcinoma.

MATERIALS AND METHODS: Fifty-six cases of renal carcinoma confirmed by histopathology underwent conventional plain CT and contrast-enhanced spectral CT at arterial phase (AP) and venous phase (VP). VNC images were generated on an AW4.6 workstation. The CT attenuation, image noise, contrast-to-noise ratio (CNR), and signal-noise-ratio (SNR) of the renal lesions and normal kidneys, long and short axis diameters of the lesion were measured from the three image sets and analysed using one-way analysis of variance (ANOVA). Two radiologists evaluated image quality subjectively using a five-point score, and lesion signature using a three-point score. Image quality scores were compared statistically and tested for consistency.

RESULTS: The two reviewers had good agreement for subjective evaluation (Kappa>0.70) and there was no difference in the quality of the scores among the three image groups. The lesion signature scores were all above the acceptable level. The CNR and SNR values in VNC were significantly higher than in TNC (p<0.05). VNC images had lower renal noise than in TNC (p<0.05). There was no difference in the long and short axis diameters of the lesion among the three image groups. VNC had higher CT attenuation values for the lesion and kidney than TNC (p<0.05), but the differences were <5 HU.

CONCLUSION: VNC images in spectral CT may be used to replace the conventional plain CT to reduce imaging duration and radiation dose in diagnosing renal carcinoma.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Ma G, Han D, Dang S, et al. Replacing true unenhanced imaging in renal carcinoma with virtual unenhanced images in dual-energy spectral CT: a feasibility study. Clin Radiol. 2020. PMID: 32993881. doi:10.1016/j.crad.2020.08.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。