文献速递泌尿生殖腹部MR

双参数MRI用于前列腺癌局部分期:与多参数MRI的评估和比较

Prostate cancer local staging using biparametric MRI: assessment and comparison with multiparametric MRI.
PubMed 文献 · Eur J Radiol · 2020-10-15

回顾性纳入92例根治性前列腺切除术前接受3T前列腺MRI的患者,4名阅片者分别基于T2W+DWI(双参数MRI)和T2W+DWI+DCE(多参数MRI)独立给出预测前列腺外延伸的Likert评分。DCE未显著提高AUC(多参数MRI AUC=0.73 vs 双参数MRI AUC=0.76),双参数MRI未导致局部分期准确率下降。

要点

  • 双参数MRI与多参数MRI对前列腺癌局部分期准确率无显著差异,DCE未显著改善AUC。
  • 与局部延伸显著相关的MRI征象包括外周带定位、病灶最大径、T2W包膜曲线状接触、包膜不规则、膨隆及精囊低信号。
  • 多参数MRI AUC=0.73(95%CI 0.655‒0.827)vs 双参数MRI AUC=0.76(95%CI 0.681‒0.846),差异未达统计学显著。

关键影像表现/征象

  • 与局部延伸显著相关的MRI征象包括病灶位于外周带(p < 0.001)、病灶最大径(p < 0.0001)、T2W上包膜曲线状接触(p < 0.0001)、T2W上包膜不规则(p < 0.0001)、T2W上膨隆(p < 0.001)及精囊低信号(p < 0.001)。

诊断标准与关键数值

  • 以Likert评分1–5分预测前列腺外延伸,多参数MRI AUC=0.73(95%CI 0.655‒0.827)vs 双参数MRI AUC=0.76(95%CI 0.681‒0.846),DCE未显著改善AUC。
  • 多变量模型经选择程序后仅保留MRI标准,与局部延伸显著相关的标准包括外周带定位(p < 0.001)、病灶最大径(p < 0.0001)、T2W包膜曲线状接触(p < 0.0001)、T2W包膜不规则(p < 0.0001)、T2W膨隆(p < 0.001)和精囊低信号(p < 0.001)。

临床应用与阅片要点

  • 双参数MRI(T2W+DWI)可用于前列腺癌局部分期评估,其分期准确率与多参数MRI相当。
  • 阅片时需关注外周带定位、病灶最大径、T2W包膜曲线状接触、包膜不规则、膨隆及精囊低信号等与局部延伸显著相关的征象。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The value of adding dynamic contrast-enhanced (DCE) imaging to T2-weighted (T2W) magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) to improve the detection and staging of prostate cancer (PCa) is unclear. The aim of this retrospective study was to compare the diagnostic performance of non-contrast biparametric MRI (bpMRI) with multiparametric MRI (mpMRI), for local staging of PCa.

METHODS: Ninety-two patients who underwent prostate MRI on a 3-Tesla MRI system before radical prostatectomy for PCa were included retrospectively. Four readers independently assigned a Likert score (ranging from 1 to 5) for predicting extra-prostatic extension (EPE) on T2W + DWI (bpMRI) and then on T2W + DWI + DCE imaging (mpMRI). MRI-based staging results were compared with radical prostatectomy histology. A prediction of EPE generalized linear mixed model was used to assess the added-value of DCE and discriminative power of staging accuracy by area under the receiver-operating curve (AUC ROC).

RESULTS: AUC was not significantly improved by DCE (mpMRI, AUC = 0.73 [95%CI: 0.655‒0.827] vs. bpMRI, AUC = 0.76 [95%CI: 0.681‒0.846]). After applying a selection procedure, only MRI criteria were retained in a multivariate model. The following criteria were significantly associated with local extension: localization in the peripheral zone (p < 0.001), maximal diameter of the lesion (<0.0001), curvilinear capsular contact on T2W (p < 0.0001), capsular irregularity on T2W (p < 0.0001), bulging on T2W (p < 0.001) and seminal vesicle hypo-signal (p < 0.001).

CONCLUSION: Use of bpMRI did not result in a decrease in local staging accuracy.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Christophe C, Montagne S, Bourrelier S, et al. Prostate cancer local staging using biparametric MRI: assessment and comparison with multiparametric MRI. Eur J Radiol. 2020. PMID: 33080549. doi:10.1016/j.ejrad.2020.109350

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。