容积多参数MRI在鉴别胰腺导管内乳头状黏液性肿瘤与浆液性囊腺瘤中的作用
研究纳入123例胰腺囊性肿瘤(≥10 mm)患者,比较IPMN与SCA的容积多参数MRI指标。SCA囊体积更大,IPMN的容积ADC更高而容积静脉强化更低。包含vADC和囊体积的模型鉴别准确率达95%,容积ADC阈值2615×10⁻⁶ mm²/s的敏感度和特异度分别为90.8%和73.5%。
要点
- IPMN囊体积小于SCA(中位2.5 cm³ vs 14.1 cm³,p<0.001)。
- IPMN容积ADC高于SCA(2925±294 vs 2521±202×10⁻⁶ mm²/s,p<0.001)。
- IPMN容积静脉强化低于SCA(37 SI vs 86 SI,p<0.001)。
关键影像表现/征象
- SCA囊体积显著大于IPMN(中位14.1 cm³,IQR 3.5-42.5 vs 中位2.5 cm³,IQR 1.1-6,p<0.001)。
- IPMN容积ADC高于SCA(2925±294×10⁻⁶ mm²/s vs 2521±202×10⁻⁶ mm²/s,p<0.001)。
- IPMN容积静脉强化低于SCA(37 SI vs 86 SI,p<0.001)。
诊断标准与关键数值
- 包含vADC和囊体积的模型鉴别IPMN与SCA的AUC准确率为95%。
- 包含ROI-ADC和轴位囊肿大小的模型鉴别IPMN与SCA的AUC准确率为84%。
- 容积ADC阈值2615×10⁻⁶ mm²/s鉴别IPMN与SCA的敏感度为90.8%、特异度为73.5%。
临床应用与阅片要点
- 作者认为容积多参数MRI可能有助于鉴别IPMN与SCA。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the use of volumetric multiparametric MRI in differentiating pancreatic intraductal papillary mucinous neoplasms (IPMNs) from serous cystadenomas (SCAs) METHODS: Included patients (123 patients with pancreatic cystic neoplasms (PCNs) measuring ≥ 10 mm) were stratified into two groups based on cyst type. Axial cyst size, region of interest (ROI)-based apparent diffusion coefficient (ADC) and volumetric data, including cyst volume, volumetric apparent diffusion coefficient (vADC), and volumetric venous enhancement (vVE) were extracted and compared between the two groups. Univariate and multiple logistic regression was used to develop models for distinguishing between IPMNs and SCAs.
RESULTS: Volume and size of the cysts, vVE and vADC and ROI-ADC were significantly different between the two groups. Cyst volume was significantly larger in SCAs (median = 14.1cm3, IQR 3.5-42.5) than in IPMNs (median = 2.5 cm3, IQR 1.1-6) (p < 0.001). IPMNs had a higher volumetric ADC value in comparison to SCAs (2925 ± 294 × 10-6 mm2/s vs 2521 ± 202 × 10-6 mm2/s, p < 0.001). However, IPMNs had lower vVE values compared to SCAs (37 signal intensity (SI) vs 86 SI, p < 0.001). Area under the ROC Curve (AUC) of the model that included vADC and cyst volume had 95% accuracy in distinguishing between the two groups. In comparison, the AUC of the model that included ROI-ADC and axial cyst size had 84% accuracy in distinguishing between the two groups. A threshold of 2615 × 10-6 mm2/s for volumetric ADC resulted in the identification of IPMNs from SCAs with sensitivity and specificity of 90.8% and 73.5%, respectively.
CONCLUSION: IPMNs had smaller cyst volume, higher volumetric ADC and lower volumetric VE values compared to SCAs. Volumetric multiparametric MRI could be useful in differentiating between the IPMN and SCA groups.
引用
- Ghadimi M, Pandey P, Rezvani Habibabadi R, et al. Role of volumetric multiparametric MRI in distinguishing between intraductal papillary mucinous neoplasms and serous cystadenoma. Abdom Radiol (NY). 2020. PMID: 33033892. doi:10.1007/s00261-020-02792-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。