腹部/盆腔CT判读中重大错误率的昼夜变化
本研究从本机构质量保证数据库收集10年间至少含一处重大错误的腹盆腔CT研究,按判读星期与时段分类,并以同期检查量归一化。共识别252处重大错误,周一最多(n=58);
要点
- 周一重大错误数最多(n=58),高于其他工作日。
- 按检查量归一化后上述时段与星期模式仍存在,提示错误率随时段与星期变化。
核心结论
- 腹部CT判读错误率似乎随一天中的时段和星期变化:工作周内上午晚些时候与临近下班时错误率最高,周一高于其他日。
研究设计与样本
- 回顾性收集本机构质量保证数据库10年间至少含一处重大错误的腹盆腔CT研究,共识别252处重大错误。
- 重大错误定义为漏诊的发现,且该漏诊以可能对患者不利的方式改变了处理。
- 按判读的星期与小时分类,并取同期检查量数据按日与时段归一化,用二项分布计算经检查量校正的错误率标准误。
- 以线性时间为预测变量的加权logistic回归模型检验错误率随时间恒定的零假设。
诊断标准与关键数值
- 重大错误定义为漏诊的发现,且该漏诊以可能对患者不利的方式改变了处理。
- 共识别252处重大错误,周一错误数最多(n=58)。
- 按日与按小时的错误率恒定性总体检验均有统计学意义(均P<0.001)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVE: Variation of visual selective attention through the day has been demonstrated in several arenas of human performance, including radiology. It is uncertain whether this variation translates to an identifiable diurnal pattern of error rates for radiology interpretation. The purpose of this study was to attempt to identify particular days of the week and times of the day when radiologists might be most prone to error.
MATERIALS AND METHODS: Abdomen/pelvis CT studies containing at least one major error were collected from a 10-year period from the quality assurance (QA) database at our institution. A major error was defined as a missed finding that had altered management in a way potentially detrimental to the patient. The identified studies were categorized by the day of the week and hour of the day that the study was interpreted. Study volume data over this same period was also obtained by day of the week and time of day, so to normalize the data based on case volume. Standard errors of the volume-adjusted error rates were obtained based on the binomial distribution. The null hypothesis of constant error rates over time was tested using a weighted logistic regression model with linear time as predictor.
RESULTS: A total of 252 major errors were identified. More errors were made on Monday than on any other day of the week (n = 58). Major error rates increased through the mid to late morning (9 am to 12 pm), and then decreased progressively through the afternoon until 4 pm, when a rise in the error rate was seen. This pattern persisted when error rates were normalized by study volume within each hour. Overall tests of time-constancy of error rates by day and hour were statistically significant (both p-values < 0.001).
CONCLUSION: Our study shows that error rates in abdominal CT do seem to vary with time of day and day of the week. During the workweek, error rates were highest in the late morning and at the close of the workday, and greater on Mondays than other days.
引用
- Kliewer MA, Mao L, Brinkman MR, et al. Diurnal variation of major error rates in the interpretation of abdominal/pelvic CT studies. Abdom Radiol (NY). 2020. PMID: 33040173. doi:10.1007/s00261-020-02807-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。