文献速递腹部泌尿生殖技术与安全CTMR

肾细胞癌患者体成分定量:计算机断层扫描与磁共振成像测量比较

Quantification of body composition in renal cell carcinoma patients: Comparing computed tomography and magnetic resonance imaging measurements.
PubMed 文献 · Eur J Radiol · 2020-09-28

本研究对58例肾细胞癌患者的术前腹部CT与MRI图像进行半自动分割,测量骨骼肌面积、肌内脂肪面积、内脏脂肪面积、皮下脂肪面积及腰大肌/椎旁肌线性測量。CT与MRI各体成分测量均呈强相关(r=0.98–0.99),Bland-Altman分析显示CT测量值偏大(SMA 1.35%、线性肌肉测量2.79%、SFA 10.34%),MRI测量值偏大(IMFA 0.75%、VFA 5.81%)。ECOG≥1与所有测量中较低的骨骼肌相关。作者认为轴向MRI可用于全面体成分测量。

要点

  • CT与MRI对骨骼肌和脂肪组织的横断面测量均呈强相关(r=0.98–0.99)。
  • Bland-Altman分析显示CT测量的SMA、线性肌肉测量和SFA值偏大,MRI测量的IMFA和VFA值偏大。
  • ECOG≥1患者在所有测量方式下骨骼肌均低于ECOG 0患者。

关键影像表现/征象

  • 半自动分割测量SMA、IMFA、VFA、SFA的相关系数r分别为0.99、0.99、0.99、0.98,骨骼肌线性测量r=0.96。
  • Bland-Altman分析显示CT测量值偏大:SMA偏大1.35%,线性肌肉测量偏大2.79%,SFA偏大10.34%。
  • Bland-Altman分析显示MRI测量值偏大:IMFA偏大0.75%,VFA偏大5.81%。
  • ECOG≥1与所有测量中较低的骨骼肌相关。

诊断标准与关键数值

  • CT与MRI测量SMA、IMFA、VFA、SFA的Pearson相关系数分别为0.99、0.99、0.99、0.98。
  • CT与MRI测量骨骼肌线性指标的Pearson相关系数为0.96。
  • Bland-Altman偏倚:SMA 1.35%(CT偏大)、线性肌肉测量2.79%(CT偏大)、SFA 10.34%(CT偏大)、IMFA 0.75%(MRI偏大)、VFA 5.81%(MRI偏大)。

临床应用与阅片要点

  • axial MRI图像可用于肾细胞癌患者全面体成分测量,与CT测量强相关。
  • 解读体成分测量时需注意CT与MRI在SFA、VFA、IMFA和线性肌肉测量上的系统偏倚。
  • ECOG≥1患者骨骼肌较低,阅片时可关注骨骼肌减少情况。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Body composition measures provide valuable information for prognostication and treatment election in cancer patients. We investigated the novel use of magnetic resonance imaging (MRI) for skeletal muscle and adipose tissue cross-sectional area measurements in preoperative renal cell carcinoma (RCC) patients.

MATERIALS AND METHODS: RCC patients with pre-operative CT and MRI abdominal imaging were identified. Semi-automatic segmentation measurement of skeletal muscle area (SMA), intramuscular fat area (IMFA), visceral fat area (VFA), subcutaneous fat area (SFA), linear measurements of psoas, paraspinal muscles were performed. Pearson correlation coefficients, Bland-Altman plot analyses were done. Multivariable regression analysis examined the relationship between patient characteristics and skeletal muscle.

RESULTS: Image analysis was performed on 58 RCC patients with preoperative CT and MRI imaging. For segmentation measures, r = 0.99, 0.99, 0.99, and 0.98 for SMA, IMFA, VFA, SFA, respectively, and 0.96 for linear measures of skeletal muscle. Bland-Altman analysis revealed a bias toward larger CT value for SMA (1.35 %), linear muscle measures (2.79 %), and SFA (10.34 %), and toward larger MRI values for IMFA (0.75 %) and VFA (5.81 %). ECOG ≥ 1 was associated with lower skeletal muscle than ECOG 0 for all measurements.

CONCLUSIONS: Strong correlation of CT and MRI cross sectional measurements of skeletal muscle and adipose tissues supports the use of axial MRI images for comprehensive measurement of body composition. This has widespread implications for body composition research and cancer patient care.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Higgins MI, Martini DJ, Patil DH, et al. Quantification of body composition in renal cell carcinoma patients: Comparing computed tomography and magnetic resonance imaging measurements. Eur J Radiol. 2020. PMID: 33010681. doi:10.1016/j.ejrad.2020.109307

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。