术中超声造影与剪切波弹性成像对胰腺肿瘤的定性及其对手术策略优化的价值
回顾性分析54例2017至2019年接受胰腺手术患者的术中超声造影(IoCEUS)与剪切波弹性成像(IoSWE)资料,并与术后组织学对照。IoCEUS定性恶性39/39、良性6/15;IoSWE定性恶性29/39、良性7/15。IoCEUS敏感度100%、特异度40%、准确率83.3%;SWE以3 m/s和28.7 kPa为阈值时敏感度74.4%、特异度46.7%、准确率66.7%。29.6%的病例术中超声结果对手术产生即时影响。
要点
- IoCEUS对胰腺局灶性病变恶性诊断敏感度100%,阴性预测值100%,但特异度仅40%。
- IoSWE以剪切波速度3 m/s、硬度28.7 kPa为阈值诊断恶性,敏感度74.4%、特异度46.7%。
- IoCEUS定性优于IoSWE,两者联合在特定病例中可能有帮助。
核心结论
- 术中剪切波弹性成像与超声造影对胰腺局灶性病变的术中定性具有很高价值,IoCEUS优于IoSWE,两者联合在特定病例中可能有帮助。
研究设计与样本
- 回顾性分析2017至2019年接受胰腺手术的54例患者,使用LOGIQ E9超声仪(GE Healthcare,芝加哥,伊利诺伊州)及3-9 MHz多频线阵/T型探头行术中CEUS与SWE,以术后组织学结果为参考标准。
关键影像表现/征象
- IoCEUS经静脉团注2.4至10 mL六氟化硫微泡后,动态分析病灶从动脉期至延迟期的微血管化,以低增强/不规则血管化作为大囊性/小实性胰腺局灶性病变的恶性标准。
- IoSWE将感兴趣区置于病灶测量剪切波速度(米/秒)与硬度(千帕)以分析胰腺局灶性病变的硬度。
诊断标准与关键数值
- IoCEUS诊断恶性:敏感度100%、特异度40%、准确率83.3%、阳性预测值81.3%、阴性预测值100%(P<.05)。
- IoSWE以剪切波速度3 m/s和硬度28.7 kPa为阈值诊断恶性:敏感度74.4%、特异度46.7%、准确率66.7%、阳性预测值78.4%、阴性预测值41.2%(P<.05)。
- 两种技术联合应用:准确率76%、敏感度74.4%、特异度33.3%。
临床应用与阅片要点
- 术中超声造影可正确识别39/39例恶性与6/15例良性胰腺局灶性病变,与术后组织学结果相关。
- 术中剪切波弹性成像可正确识别29/39例恶性与7/15例良性胰腺局灶性病变。
- 29.6%的病例术中超声结果对手术产生即时影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate intraoperative contrast-enhanced ultrasound (IoCEUS) and intraoperative shear wave elastography (IoSWE) for characterization of focal pancreatic lesions (FPLs) in correlation with postoperative histologic results. Thereby, the impact of intraoperative ultrasound (US) on pancreas surgery was evaluated.
METHODS: Intraoperative CEUS and SWE data from 54 patients, who underwent pancreas surgery between 2017 and 2019, were analyzed retrospectively. Ultrasound examinations were performed with multifrequency linear/T-shaped transducers (3-9 MHz) on a high-end US device (LOGIQ E9; GE Healthcare, Chicago, IL). To analyze FPL stiffness by SWE, regions of interest were placed to measure the shear wave speed (meters per second) and stiffness (kilopascals). After intravenous bolus injections of 2.4 to 10 mL of sulfur hexafluoride microbubbles, a dynamic analysis of FPL microvascularization from arterial to late phases was performed using IoCEUS considering hypoenhancement/irregular vascularization of macrocystic/small solid FPL malignancy criteria. Ultrasound findings were correlated with postoperative histologic results. The impact of intraoperative US on surgery was documented in each case.
RESULTS: Of 54 FPLs, IoCEUS could correctly characterize 39 of 39 malignant and 6 of 15 benign FPLs; IoSWE 29 of 39 as malignant and 7 of 15 as benign. Intraoperative CEUS's sensitivity was 100%; specificity, 40%; accuracy, 83.3%; positive predictive value, 81.3%; and negative predictive value, 100% (P < .05). Applying cutoff values of 3 m/s and 28.7 kPa, SWE's sensitivity was 74.4%; specificity, 46.7%; accuracy, 66.7%; positive predictive value; 78.4%; and negative predictive value, 41.2% for cancer detection (P < .05). The combined use of both techniques showed an accuracy rate of 76%, sensitivity of 74.4%, and specificity of 33.3%. In 29.6%, US results had an immediate impact on surgery.
CONCLUSIONS: Intraoperative SWE and CEUS are highly valuable techniques for intraoperative characterization of FPLs. Although IoCEUS proved to be superior to IoSWE, the combined use can be helpful in particular cases.
引用
- Platz Batista da Silva N, Engeßer M, Hackl C, et al. Intraoperative Characterization of Pancreatic Tumors Using Contrast-Enhanced Ultrasound and Shear Wave Elastography for Optimization of Surgical Strategies. J Ultrasound Med. 2020. PMID: 33124700. doi:10.1002/jum.15545
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。