文献速递腹部MR

3.0特斯拉下SE-MRE衍生剪切硬度评估用于实性肝脏肿瘤表征

Assessment of SE-MRE-derived shear stiffness at 3.0 Tesla for solid liver tumors characterization.
PubMed 文献 · Abdom Radiol (NY) · 2020-10-24

前瞻性纳入55例实性局灶性肝脏病变患者,于3.0T行2D自旋回波MR弹性成像(SE-MRE)测量病变硬度。57个病变中34个恶性、23个良性,以5.8 kPa为阈值区分良恶性,特异度88%,准确度依阅片者不同为75%–85%,阅片者间相关系数0.94。

要点

  • 3.0T 2D-SE-MRE测量肝脏病变硬度技术成功率91.23%。
  • 恶性病变中位硬度6.8±1.7或7.5±1.5 kPa(依阅片者),良性为4.5±1.5 kPa。
  • 以5.8 kPa为阈值区分良恶性,特异度88%,准确度75%–85%(依阅片者)。

关键影像表现/征象

  • SE-MRE硬度测量在91.23%的病变中技术成功。
  • 良性病变中位硬度为4.5±1.5 kPa;恶性病变中位硬度依阅片者不同分别为6.8±1.7 kPa和7.5±1.5 kPa。

诊断标准与关键数值

  • 以5.8 kPa为硬度阈值区分恶性与良性病变,特异度88%,准确度依阅片者不同为75%–85%。
  • 阅片者间一致性为0.90±0.04,相关系数0.94。

临床应用与阅片要点

  • 3.0T 2D-SE-MRE测量实性局灶性肝脏病变硬度可用于辅助区分良恶性,阈值5.8 kPa时特异度88%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the feasibility and diagnostic value of using a 2D spin-echo MR elastography (SE-MRE) sequence at 3.0 Tesla for solid focal liver lesions (FLL) characterization.

METHODS: This prospective study included 55 patients with solid FLL (size > 20 mm), who underwent liver SE-MRE at 3 Tesla between 2016 and 2019. Stiffness measurements were performed by two independent readers blinded to the complete MRI exam or patient information. Histological confirmation or typical behavior on the complete MRI exam evaluated in consensus by expert abdominal radiologists was used as reference standard. FLLs were grouped and compared (malignant vs. benign) using the Mann-Whitney and Kruskal-Wallis tests. MRE diagnostic performance was assessed, and stiffness cutoffs were obtained by analysis of ROC curves from accuracy maximization. A linear regression plot was used to evaluate inter-rater agreement for FLLs stiffness measurements. p values < 0.05 were considered statistically significant.

RESULTS: The final study group comprised 57 FLLs (34 malignant, 23 benign). Stiffness measurements were technically successful in 91.23% of lesions. To both readers, the median stiffness of the lesions categorized as benign was 4.5 ± 1.5 kPa and in the malignant group 6.8 ± 1.7 and 7.5 ± 1.5 kPa depending on the reader. A cutoff of 5.8 kPa distinguished malignant and benign lesions with 88% specificity and 75-85% accuracy depending on the reader. The inter-rater agreement was 0.90 ± 0.04 with a correlation coefficient of 0.94.

CONCLUSION: 2D-SE-MRE at 3.0 T provides high specificity and PPV to differentiate benign from malignant liver lesions. Trial registration 18FFUA-A02.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Dominguez A, Fino D, Spina JC, et al. Assessment of SE-MRE-derived shear stiffness at 3.0 Tesla for solid liver tumors characterization. Abdom Radiol (NY). 2020. PMID: 33098479. doi:10.1007/s00261-020-02828-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。