研究纳入82例慢性乙型肝炎患者和30名健康志愿者,在3T MRI上行13个b值的DWI,比较单指数、双指数和拉伸指数模型的扩散参数对肝纤维化分期和炎症活动度分级的价值。结果显示Dt和DDC与纤维化分期和炎症分级均呈负相关,在鉴别显著纤维化(≥F2)和进展期纤维化(≥F3)时Dt和DDC的AUC显著高于ADCst,但在检测炎症活动度≥A2/A3时各参数AUC无显著差异。
要点
- Dt和DDC在鉴别显著纤维化(≥F2)和进展期纤维化(≥F3)时AUC显著高于ADCst。
- ADCst、Dt和DDC均与纤维化分期和炎症活动度分级呈负相关(P<0.001)。
- 检测炎症活动度≥A2/A3时Dt和DDC的AUC虽高于ADCst但差异无统计学意义。
诊断标准与关键数值
- 纤维化分期分布(METAVIR):F0 n=1,F1 n=16,F2 n=31,F3 n=19,F4 n=15。
- 炎症活动度分级分布(METAVIR):A0 n=1,A1 n=14,A2 n=46,A3 n=21。
- ADCst、Dt和DDC与纤维化分期呈负相关(r分别为-0.418、-0.717、-0.630,均P<0.001)。
- ADCst、Dt和DDC与炎症活动度分级呈负相关(r分别为-0.514、-0.626、-0.550,均P<0.001)。
- 鉴别显著纤维化(≥F2)和进展期纤维化(≥F3)时,Dt的AUC分别为0.854和0.881,DDC的AUC分别为0.794和0.834,均显著高于ADCst的AUC(分别为0.637和0.717)(均P<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the value of various diffusion parameters obtained from monoexponential, biexponential, and stretched-exponential diffusion-weighted imaging (DWI) models for staging hepatic fibrosis (HF) and grading inflammatory activity in patients with chronic hepatitis B (CHB).
METHODS: 82 patients with CHB and 30 healthy volunteers underwent DWI with 13 b-values on a 3T MRI unit. The standard apparent diffusion coefficient (ADCst) was calculated using a monoexponential model. The true diffusion coefficient (Dt), pseudo-diffusion coefficient (Dp), and perfusion fraction (f) were calculated using a biexponential model. The distributed diffusion coefficient (DDC) and water-molecule diffusion heterogeneity index (α) were calculated using a stretched-exponential model. Receiver operating characteristic (ROC) curves were performed for diffusion parameters to compare the diagnosis performance.
RESULTS: The distributions of hepatic fibrosis stages and the inflammatory activity grades (METAVIR scoring system) were as follows: F0, n = 1; F1, n = 16; F2, n = 31; F3, n = 19; and F4, n = 15. A0, n = 1; A1, n = 14; A2, n = 46; and A3, n = 21. ADCst, Dt and DDC values showed negative correlation with the fibrosis stage (r = - 0.418, - 0.717 and - 0.630, all P < 0.001) and the inflammatory activity grade (r = - 0.514, - 0.626 and - 0.550, all P < 0.001). The area under the ROC curve (AUC) of Dt (AUC = 0.854, 0.881) and DDC (AUC = 0.794, 0.834) were significantly higher than that of ADCst (AUC = 0.637, 0.717) in discriminating significant fibrosis (≥ F2) and advanced fibrosis (≥ F3) (all P < 0.05). Although Dt (AUC = 0.867, 0.836) and DDC (AUC = 0.810, 0.808) showed higher AUCs than ADCst (AUC = 0.767, 0.803), there was no significant difference in their ability in detecting inflammatory activity grade ≥ A2/A3 (P > 0.05).
CONCLUSIONS: Dt and DDC are promising indicators and outperform ADCst for staging HF. While both Dt and DDC have similar diagnostic performance compared with ADCst for grading inflammatory activity.
引用
- Fu F, Li X, Liu Q, et al. Noninvasive DW-MRI metrics for staging hepatic fibrosis and grading inflammatory activity in patients with chronic hepatitis B. Abdom Radiol (NY). 2020. PMID: 33074424. doi:10.1007/s00261-020-02801-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。