床旁超声预测危重患者静息能量消耗的新用途
研究纳入69例危重患者,用间接测热法测静息能量消耗(REE_IC),并测肱二头肌与股四头肌肌肉层厚度及心输出量;随机分为模型开发组46例和交叉验证组23例。开发组建立REE_US公式(R²=0.8),验证组REE_US与REE_IC均值差-66 kcal/d(-3.3%,P=.14),而Harris-Benedict公式与REE_IC均值差455.8 kcal/d(26%,P<.001);Bland-Altman分析显示REE_US与REE_IC一致性良好。
要点
- 床旁超声测量肌肉层厚度和心输出量可用于估算危重患者静息能量消耗。
- REE_US公式为206+173.5×CO+137×MLT-230×(女性=1;男性=0),R²=0.8。
- 交叉验证组REE_US与间接测热法一致性良好,Harris-Benedict公式一致性不佳。
关键影像表现/征象
- 肌肉层厚度测量部位为肱二头肌和股四头肌。
- 模型开发组采用多元回归分析生成REE_US值。
- 交叉验证组计算REE_US和REE_HB并与REE_IC比较。
诊断标准与关键数值
- REE_US预测公式:预测REE_US(kcal/d)=206+173.5×CO(L/min)+137×MLT(cm)-230×(女性=1;男性=0)(R²=0.8;P<.0001)。
- 交叉验证组REE_IC与REE_US均值差-66(-3.3%)kcal/d(P=.14)。
- 交叉验证组REE_IC与REE_HB均值差455.8(26%)kcal/d(P<.001)。
- Bland-Altman分析显示REE_US与REE_IC一致性良好,REE_HB与REE_IC一致性不佳。
临床应用与阅片要点
- 作者结论认为静息能量消耗可从肌肉层厚度和心输出量的超声测量中估算。
- 床旁超声模型可解释危重患者REE变化的80%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Accurate estimation of a critically ill patient's caloric requirements is essential for a proper nutritional plan. This study aimed to evaluate the use of point-of-care ultrasound (US) to predict the resting energy expenditure (REE) in critically ill patients.
METHODS: In 69 critically ill patients, we measured the REE using indirect calorimetry (REE_IC), muscle layer thicknesses (MLTs), and cardiac output (CO). Muscle thickness was measured at the biceps and the quadriceps muscles. Patients were randomly split into a model development group (n = 46) and a cross-validation group (n = 23). In the model development group, a multiple regression analysis was applied to generate REE using US (REE_US) values. In the cross-validation group, REE was calculated by the REE_US and the resting energy expenditure using the Harris-Benedict equation (REE_HB), and both were compared to the REE_IC.
RESULTS: In the model development group, the REE_US was predicted by the following formula: predicted REE_US (kcal/d) = 206 + 173.5 × CO (L/min) + 137 × MLT (cm) - 230 × (women = 1; men = 0) (R2 = 0.8; P < .0001). In the cross-validated group, the REE_IC and REE_US values were comparable (mean difference, -66 [-3.3%] kcal/d; P = .14). However, the difference between the mean REE_IC and the mean REE_HB was 455.8 (26%) kcal/d (P < .001). According to a Bland-Altman analysis, the REE_US agreed well with the REE_IC, whereas the REE_HB did not.
CONCLUSIONS: Resting energy expenditure could be estimated from US measurements of MLTs and CO. Our point-of-care US model explains 80% of the change in the REE in critically ill patients.
引用
- Mukhtar A, Abdelghany M, Hasanin A, et al. The Novel Use of Point-of-Care Ultrasound to Predict Resting Energy Expenditure in Critically Ill Patients. J Ultrasound Med. 2020. PMID: 33085099. doi:10.1002/jum.15538