双层光谱探测器CT虚拟单能图像与传统多能图像评估颈动脉粥样硬化斑块负荷及衰减的对比

Plaque burden assessment and attenuation measurement of carotid atherosclerotic plaque using virtual monoenergetic images in comparison to conventional polyenergetic images from dual-layer spectral detector CT.
PubMed 文献 · Eur J Radiol · 2020-09-23

回顾性分析30例患者50个颈动脉斑块的DLCTA图像,比较虚拟单能图像(VMI)与传统多能图像(PI)在斑块负荷和衰减测量中的差异。结果显示40–120 keV VMI与PI在管腔面积、壁面积和NWI上无显著差异,钙化面积有显著差异;非钙化成分衰减在50–120 keV与PI相当,钙化成分在60–120 keV与PI相当。作者认为VMI可能提供更多斑块特征信息。

要点

  • 40–120 keV VMI与PI在颈动脉斑块管腔面积、壁面积及NWI上无显著差异。
  • VMI与PI在钙化面积上存在显著差异(p=0.009)。
  • 非钙化斑块成分衰减在50–120 keV VMI与PI相当,钙化成分在60–120 keV与PI相当。

核心结论

  • 40–120 keV VMI与PI在颈动脉斑块负荷评估上相当;非钙化成分衰减在50–120 keV VMI与PI相当;VMI可能提供更多颈动脉斑块特征信息。

研究设计与样本

  • 回顾性分析30例患者(8例女性,平均年龄63.1±7.5岁)的主动脉上段DLCTA图像,共分析50个颈动脉斑块(左侧27个,右侧23个),比较PI与不同VMI。

关键影像表现/征象

  • PI上管腔面积平均34.50±20.57 mm²,壁面积平均47.61±19.94 mm²,钙化面积中位数5.25 mm²(范围1.35–51.86 mm²),NWI平均0.59±0.16。
  • 非钙化、钙化成分及胸锁乳突肌的有效Z值分别为7.67±0.42、11.70±1.22和7.45±0.12。

诊断标准与关键数值

  • 斑块负荷以归一化壁指数(NWI)评估,不同VMI与PI间NWI无显著差异(p=0.980)。
  • 管腔面积(p=0.314)和壁面积(p=0.600)在不同VMI与PI间无显著差异,钙化面积有显著差异(p=0.009)。
  • 非钙化成分衰减在50–120 keV VMI与PI相当(所有p>0.05),钙化成分在60–120 keV VMI与PI相当(所有p>0.05)。

临床应用与阅片要点

  • 在DLCTA中,40–120 keV VMI可用于颈动脉斑块负荷评估,结果与PI相当。
  • 测量非钙化斑块成分衰减时可选用50–120 keV VMI,测量钙化成分衰减时可选用60–120 keV VMI。
  • 作者认为VMI可能提供更多颈动脉斑块特征信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare virtual monoenergetic images (VMIs) with conventional polyenergetic images (PI) of Dual-layer spectral detector CT angiography (DLCTA) in plaque burden assessment and attenuation measurement of carotid atherosclerotic plaques.

METHODS: Supra-aortic DLCTA imaging of thirty patients (8 female, mean ages 63.1 ± 7.5 years) were respectively reviewed. Lumen area, wall area, and calcified area of plaques were outlined and recorded. Normalized wall index (NWI) was calculated for plaque burden and compared between PI and different VMIs. The attenuation of the non-calcified, calcified area of the plaques, sternocleidomastoid muscle (SCM), as well as Z effective values were measured and compared.

RESULTS: Fifty carotid plaques (27 left, 23 right) of thirty patients were analyzed. The average values of lumen, wall, calcified areas and NWI on PI were 34.50 ± 20.57mm2, 47.61 ± 19.94 mm2, 5.25 mm2 (1.35- 51.86 mm2), and 0.59 ± 0.16 respectively. No significant difference was found in the lumen area (p = 0.314), wall area (p = 0.600), and NWI (p = 0.980) between different VMIs and PI. A significant difference was found in the calcified area between VMIs and PI (p = 0.009). Attenuations of non-calcified and calcified components in carotid plaques were comparable to PI for 50-120 keV (all: p > 0.05) and 60-120 keVs (all p > 0.05), respectively. Z Effective values for non-calcified, calcified and SCM were 7.67 ± 0.42, 11.70 ± 1.22, and 7.45 ± 0.12, respectively.

CONCLUSIONS: Carotid plaque burden assessment was comparable between PI and VMIs at 40-120 keVs. Attenuations of non-calcified components in carotid plaques were comparable to PI for 50-120 keV VMIs of DLCTA. VMIs might provide more information on carotid plaque features.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Bai X, Gao P, Zhang D, et al. Plaque burden assessment and attenuation measurement of carotid atherosclerotic plaque using virtual monoenergetic images in comparison to conventional polyenergetic images from dual-layer spectral detector CT. Eur J Radiol. 2020. PMID: 33007518. doi:10.1016/j.ejrad.2020.109302