对比剂密度与管电压设置对冠状动脉CT血管成像中钙化斑块可检测性的影响

Influence of contrast material density and kV setting on detectability of calcified plaques on coronary CT angiography.
PubMed 文献 · Eur J Radiol · 2020-09-11

研究纳入164例疑似冠心病患者,行钙化积分扫描后按自动管电压选择行冠状动脉CT血管成像,比较高浓度对比剂(400 mgI/mL,127例)与低浓度对比剂(280 mgI/mL,37例)对钙化斑块检出敏感度的影响。低浓度对比剂组总体敏感度显著高于高浓度组(79% vs 73%,p=0.0035),70 kV时差异更明显(70% vs 57.1%,p=0.0082)。作者认为常规使用高浓度对比剂的低kV冠状动脉CT血管成像会降低钙化斑块可感知性,可能低估狭窄。

要点

  • 低浓度对比剂组检出钙化斑块的总体敏感度高于高浓度组(79% vs 73%,p=0.0035)。
  • 70 kV条件下低浓度对比剂组敏感度70%,高浓度组57.1%(p=0.0082)。
  • 高浓度对比剂在低kV时血管密度超过钙化斑块密度,可能掩盖钙化导致低估狭窄。

核心结论

  • 常规使用高浓度对比剂的低kV冠状动脉CT血管成像会降低钙化斑块可感知性,并可能低估狭窄。
  • 作者认为有必要使用较低碘浓度对比剂行低kV冠状动脉CT血管成像,并可受益于高达77.7%的剂量降低。

研究设计与样本

  • 研究纳入164例连续疑似冠心病患者(男性65.9%,平均年龄57.1±11.3岁),行钙化积分扫描后行基于定位像自动管电压选择的冠状动脉CT血管成像(70、80、90、100或120 kV)。
  • 127例患者注射50 mL碘浓度400 mgI/mL对比剂(高浓度组),37例患者注射50 mL碘浓度280 mgI/mL对比剂(低浓度组)。
  • 以钙化积分扫描为金标准计算冠状动脉CT血管成像检出钙化斑块的敏感度,并通过感兴趣区测量定量对比剂增强冠状动脉血管与钙化斑块的密度。

关键影像表现/征象

  • 高浓度对比剂增强的冠状动脉血管密度值超过钙化斑块密度值,尤其在低kV水平时。
  • 低浓度对比剂组除70 kV设置外,钙化斑块的密度值高于增强血管密度值。

诊断标准与关键数值

  • 以钙化积分扫描为金标准,冠状动脉CT血管成像检出钙化斑块的总体敏感度低浓度对比剂组79% vs 高浓度组73%(p=0.0035)。
  • 70 kV条件下低浓度对比剂组敏感度70% vs 高浓度组57.1%(p=0.0082)。

临床应用与阅片要点

  • 作者认为低kV冠状动脉CT血管成像使用较低碘浓度对比剂是必要的。
  • 作者指出使用较低碘浓度对比剂还可受益于高达77.7%的剂量降低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To analyze the impact of tube potential and iodine concentration on the visibility of calcified plaques in coronary computed tomography angiography (cCTA).

METHODS & MATERIALS: 164 consecutive patients (65.9 % men and a mean age of 57.1 ± 11.3 years) with suspected coronary artery disease underwent calcium scoring (CaSc) scan followed by cCTA with topogram-based automated tube voltage selection (70 kV, 80 kV, 90 kV, 100 kV or 120 kV). In 127 Patients (HC), we injected 50 mL of contrast material (CM) with a concentration of 400 mg iodine per ml and in 37 patients (LC) 50 mL iodine concentration of 280 mg/mL. Sensitivity of cCTA for detecting calcified plaques was calculated with CaSc serving as gold standard. Density of CM enhanced coronary vessels and calcified plaques were quantified by region-of-interest (ROI) measurements in unenhanced and cCTA image series.

RESULTS: Overall sensitivity of cCTA to detect calcified plaques was significantly higher using LC compared to HC (79 % vs. 73 %; p = 0.0035). The impact of LC was impressive at 70 kV with an improved sensitivity of 70 % vs. 57.1 % in HC (p = 0.0082). Furthermore, density values of HC enhanced coronary vessels exceeded those of calcified plaques, especially at low kV levels. In LC, except for the 70 kV setting, higher density values were shown for calculi than enhanced vessels.

CONCLUSION: Low kV cCTA in routine using highly concentrated CM leads to reduced calcified plaque perceptibility and hence potentially underestimation of stenosis. Thus, low kV cCTA using CM with lower iodine concentration is necessary. In addition, a dose reduction up to 77.7 % can also be benefited.

来源:Eur J Radiol,查看原文。版权归原作者所有。