CT在经导管二尖瓣置换术前评估与术后评价中的应用
经导管二尖瓣置换术(TMVR)适用于二尖瓣外科手术高危且不适合缘对缘修复的患者,CT凭借高各向同性空间分辨率、多平面重建能力等优势,是术前规划的关键影像手段,可用于测量二尖瓣环、模拟新左心室流出道(LVOT)以预测梗阻风险、评估着陆区解剖及入路,并模拟透视角度;术后随访CT有助于识别LVOT梗阻、瓣周漏、假性动脉瘤和瓣膜栓塞等并发症。
要点
- CT可准确测量二尖瓣环面积、周长、三角间距离、交界间距离及室间隔-侧壁距离,是TMVR术前规划的基础。
- 在CT数据中置入虚拟瓣膜可模拟新左心室流出道(neo-LVOT),用于预测TMVR所致LVOT梗阻风险。
- 随访CT有助于识别LVOT梗阻、瓣周漏、假性动脉瘤和瓣膜栓塞等TMVR并发症。
诊断标准与关键数值
- CT可测量二尖瓣环面积、周长、三角间距离、交界间距离及室间隔-侧壁距离。
- 通过在CT数据中置入虚拟瓣膜模拟新左心室流出道(neo-LVOT),以预测TMVR所致LVOT梗阻风险。
临床应用与阅片要点
- CT可用于评估着陆区解剖、瓣下结构以及虚拟装置与冠状静脉窦、左回旋支冠状动脉等邻近结构的关系。
- CT可模拟操作过程中的透视角度。
- CT可用于评估经心尖入路的胸壁条件和经房间隔入路的房间隔条件。
- 术后随访CT有助于识别LVOT梗阻、瓣周漏、假性动脉瘤和瓣膜栓塞等并发症。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Transcatheter mitral valve replacement (TMVR) is a catheter-based interventional technique for treating mitral valve disease in patients who are at high risk for open mitral valve surgery and with unfavorable anatomy for minimally invasive edge-to-edge transcatheter mitral valve repair. There are several TMVR devices with different anchoring mechanisms, delivered by either transapical or transseptal approaches. Transthoracic echocardiography is the first-line imaging modality used for characterization and quantification of mitral valve disorders. CT is complementary to echocardiography and has several advantages, including high isotropic spatial resolution, good temporal resolution, large field of view, multiplanar reconstruction capabilities, and rapid turnaround time. CT is essential for multiple aspects of preprocedural planning. Accurate and reproducible techniques to prescribe the mitral annulus at CT have been described from which important measurements such as the area, perimeter, trigone-trigone distance, intercommissural distance, and septolateral distance are obtained. The neo-left ventricular outflow tract (LVOT) can be simulated by placing a virtual prosthesis in the CT data to predict the risk of TMVR-induced LVOT obstruction. The anatomy of the landing zone and subvalvular apparatus as well as the relationship of the virtual device to adjacent structures such as the coronary sinus and left circumflex coronary artery can be evaluated. CT also stimulates procedural fluoroscopic angles. CT can be used to evaluate the chest wall for transapical access and the atrial septum for transseptal access. Follow-up CT is useful in identifying complications such as LVOT obstruction, paravalvular leak, pseudoaneurysm, and valve embolization. Online supplemental material is available for this article. ©RSNA, 2020.
引用
- Ranganath P, Moore A, Guerrero M, et al. CT for Pre- and Postprocedural Evaluation of Transcatheter Mitral Valve Replacement. Radiographics. 2020. PMID: 33001784. doi:10.1148/rg.2020200027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。