文献速递心血管MRDSA

心血管磁共振像素级定量灌注图评估多支冠状动脉病变

Assessment of Multivessel Coronary Artery Disease Using Cardiovascular Magnetic Resonance Pixelwise Quantitative Perfusion Mapping.
PubMed 文献 · JACC Cardiovasc Imaging · 2020-10-01

在2中心纳入151例受试者,行负荷灌注心血管磁共振(CMR)灌注图及有创冠状动脉造影与冠脉生理评估,比较多支冠状动脉病变(MVCAD)中定量灌注图与首过灌注图像视觉评估的诊断准确性。灌注图较视觉评估识别出更多灌注缺损节段,MVCAD缺血负荷更高,正确识别冠脉病变范围的比例为78%对58%,主要因对3支病变(87%对40%)和2支病变(71%对48%)识别更优。

要点

  • 灌注图在MVCAD中识别灌注缺损节段中位数12个,视觉评估为8个(P<0.001)。
  • 3支病变缺血负荷灌注图100%对首过法56%,2支病变63%对41%(均P<0.001)。
  • 正确识别冠脉病变范围灌注图78%对视觉评估58%(P<0.001)。

核心结论

  • 首过负荷灌注视觉评估低估MVCAD的缺血负荷。
  • 像素级定量灌注图提高CMR正确识别冠状动脉病变范围的准确性。
  • 作者认为这对缺血评估和治疗决策有重要意义。

研究设计与样本

  • 研究类型为在2个中心招募受试者的诊断准确性比较研究。
  • 共纳入151例受试者,行负荷灌注CMR(含心肌灌注图)及有创冠状动脉造影与冠脉生理评估。
  • 缺血负荷分别采用首过图像视觉评估和灌注图定量测量负荷心肌血流量评估。
  • MVCAD定义为2支病变(2VD)或3支病变(3VD),共95例。

关键影像表现/征象

  • MVCAD患者中灌注图识别灌注缺损节段中位数为每例12个(IQR 9–16),视觉评估为8个(IQR 5–9.5),P<0.001。
  • 3VD缺血负荷灌注图为100%(75%–100%),首过法为56%(38%–81%),P<0.001。
  • 2VD缺血负荷灌注图为63%(50%–75%),首过法为41%(31%–50%),P<0.001。
  • 单支病变缺血负荷灌注图为25%(13%–44%),首过法为25%(13%–31%),两者无差异。

诊断标准与关键数值

  • 正确识别冠状动脉病变范围的比例:灌注图78%对视觉评估58%(P<0.001)。
  • 正确识别3VD的比例:灌注图87%对视觉评估40%。
  • 正确识别2VD的比例:灌注图71%对视觉评估48%。

临床应用与阅片要点

  • 在MVCAD中,首过灌注视觉评估可能低估缺血负荷,灌注图可提供更高的缺血负荷测量值。
  • 灌注图较视觉评估识别出更多灌注缺损节段,并提高正确识别病变范围的比例。
  • 作者认为该结果对缺血评估和治疗决策有重要意义。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The authors sought to compare the diagnostic accuracy of quantitative perfusion maps to visual assessment (VA) of first-pass perfusion images for the detection of multivessel coronary artery disease (MVCAD).

BACKGROUND: VA of first-pass stress perfusion cardiac magnetic resonance (CMR) may underestimate ischemia in MVCAD. Pixelwise perfusion mapping allows quantitative measurement of regional myocardial blood flow, which may improve ischemia detection in MVCAD.

METHODS: One hundred fifty-one subjects recruited at 2 centers underwent stress perfusion CMR with myocardial perfusion mapping, and invasive coronary angiography with coronary physiology assessment. Ischemic burden was assessed by VA of first-pass images and by quantitative measurement of stress myocardial blood flow using perfusion maps.

RESULTS: In patients with MVCAD (2-vessel [2VD] or 3-vessel disease [3VD]; n = 95), perfusion mapping identified significantly more segments with perfusion defects (median segments per patient 12 [interquartile range (IQR): 9 to 16] by mapping vs. 8 [IQR: 5 to 9.5] by VA; p < 0.001). Ischemic burden (IB) measured using mapping was higher in MVCAD compared with IB measured using VA (3VD mapping 100 % (75% to 100%) vs. first-pass 56% (38% to 81%) ; 2VD mapping 63% (50% to 75%) vs. first-pass 41% (31% to 50%); both p < 0.001), but there was no difference in single-vessel disease (mapping 25% (13% to 44%) vs. 25% (13% to 31%). Perfusion mapping was superior to VA for the correct identification of extent of coronary disease (78% vs. 58%; p < 0.001) due to better identification of 3VD (87% vs. 40%) and 2VD (71% vs. 48%).

CONCLUSIONS: VA of first-pass stress perfusion underestimates ischemic burden in MVCAD. Pixelwise quantitative perfusion mapping increases the accuracy of CMR in correctly identifying extent of coronary disease. This has important implications for assessment of ischemia and therapeutic decision-making.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Kotecha T, Chacko L, Chehab O, et al. Assessment of Multivessel Coronary Artery Disease Using Cardiovascular Magnetic Resonance Pixelwise Quantitative Perfusion Mapping. JACC Cardiovasc Imaging. 2020. PMID: 33011115. doi:10.1016/j.jcmg.2020.06.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。