基于深度学习的降噪联合迭代重建用于胸部超低剂量CT:图像质量与Lung-RADS评估

Combination of Deep Learning-Based Denoising and Iterative Reconstruction for Ultra-Low-Dose CT of the Chest: Image Quality and Lung-RADS Evaluation.
PubMed 文献 · AJR Am J Roentgenol · 2020-10-14

回顾性评估41例患者252个肺结节的胸部超低剂量CT(平均0.19 mSv)与标准剂量CT(6.46 mSv),比较混合迭代重建(HIR)、基于模型的迭代重建(MBIR)及联合深度学习降噪(DLD)的图像质量与Lung-RADS评估。DLD可改善HIR和MBIR的图像质量,MBIR-DLD在图像质量和Lung-RADS评估上均优于HIR-DLD。

要点

  • 在超低剂量胸部CT中,深度学习降噪可提升HIR与MBIR的图像质量。
  • MBIR-DLD图像质量最佳,Lung-RADS与标准剂量CT的一致性良好(κw=0.70和0.72)。
  • HIR的Lung-RADS一致性仅为一般至中等(κw=0.46和0.32)。

核心结论

  • 深度学习降噪可改善超低剂量CT中HIR和MBIR的图像质量。
  • MBIR-DLD在图像质量和Lung-RADS评估方面均优于HIR-DLD。

研究设计与样本

  • 回顾性评估41例患者共252个结节。
  • 所有患者均接受超低剂量CT(平均±标准差,0.19±0.01 mSv)和标准剂量CT(6.46±2.28 mSv)。
  • 超低剂量CT图像采用HIR和MBIR重建,并用DLD后处理(即HIR-DLD和MBIR-DLD);标准剂量CT图像采用滤波反投影重建。

诊断标准与关键数值

  • 三名独立放射科医师按5分制对噪声、条纹伪影、结节边缘、小血管清晰度、正常肺实质均匀性和整体图像质量进行主观评分。
  • 两名放射科医师依据Lung-RADS分别用HIR、MBIR、HIR-DLD、MBIR-DLD的超低剂量CT图像及标准剂量CT图像独立评估结节。
  • HIR的Lung-RADS一致性为一般或中等(读者1和读者2:κw=0.46和0.32)。
  • MBIR一致性为中等或良好(κw=0.68和0.57),HIR-DLD为中等(κw=0.53和0.48),MBIR-DLD为良好(κw=0.70和0.72)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The objective of our study was to assess the effect of the combination of deep learning-based denoising (DLD) and iterative reconstruction (IR) on image quality and Lung Imaging Reporting and Data System (Lung-RADS) evaluation on chest ultra-low-dose CT (ULDCT). MATERIALS AND METHODS. Forty-one patients with 252 nodules were evaluated retrospectively. All patients underwent ULDCT (mean ± SD, 0.19 ± 0.01 mSv) and standard-dose CT (SDCT) (6.46 ± 2.28 mSv). ULDCT images were reconstructed using hybrid iterative reconstruction (HIR) and model-based iterative reconstruction (MBIR), and they were postprocessed using DLD (i.e., HIR-DLD and MBIR-DLD). SDCT images were reconstructed using filtered back projection. Three independent radiologists subjectively evaluated HIR, HIR-DLD, MBIR, and MBIR-DLD images on a 5-point scale in terms of noise, streak artifact, nodule edge, clarity of small vessels, homogeneity of the normal lung parenchyma, and overall image quality. Two radiologists independently evaluated the nodules according to Lung-RADS using HIR, MBIR, HIR-DLD, and MBIR-DLD ULDCT images and SDCT images. The median scores for subjective analysis were analyzed using Wilcoxon signed rank test with Bonferroni correction. Intraobserver agreement for Lung-RADS category between ULDCT and SDCT was evaluated using the weighted kappa coefficient. RESULTS. In the subjective analysis, ULDCT with DLD showed significantly better scores than did ULDCT without DLD (p < 0.001), and MBIR-DLD showed the best scores among the ULDCT images (p < 0.001) for all items. In the Lung-RADS evaluation, HIR showed fair or moderate agreement (reader 1 and reader 2: κw = 0.46 and 0.32, respectively); MBIR, moderate or good agreement (κw = 0.68 and 0.57); HIR-DLD, moderate agreement (κw = 0.53 and 0.48); and MBIR-DLD, good agreement (κw = 0.70 and 0.72). CONCLUSION. DLD improved the image quality of both HIR and MBIR on ULDCT. MBIR-DLD was superior to HIR_DLD for image quality and for Lung-RADS evaluation.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。