123I-FP-CIT SPECT 特异性结合比在进行性核上性麻痹中的诊断效能:与核心临床特征及 MRI 的比较
研究纳入 53 例临床疑似进行性核上性麻痹(PSP)患者,比较 123I-FP-CIT SPECT 特异性结合比(SBR)、MRI 帕金森指数(MRPI)及核心临床特征对 PSP 的诊断效能。结果显示 MRPI(截断值 >11.6)特异度 100%、敏感度 85.0%,SBR(截断值 <3.7)敏感度 95.0%、特异度 36.4%,两者作用互补。
要点
- MRPI 截断值 >11.6 时诊断 PSP 特异度 100%、敏感度 85.0%、准确率 94.3%。
- 123I-FP-CIT SPECT SBR 截断值 <3.7 时敏感度 95.0%,但特异度仅 36.4%、准确率 58.5%。
- 作者认为 SPECT 与 MRI 作用互补,联合使用可能更有助于有信心地做出 PSP 临床诊断。
核心结论
- 123I-FP-CIT SPECT 对 PSP 诊断敏感度高,MRI 对 PSP 诊断特异度高。
- 作者认为两者作用互补,联合使用可能有助于更有信心地做出 PSP 临床诊断。
研究设计与样本
- 研究纳入 53 例临床疑似 PSP 且接受 123I-FP-CIT SPECT 与 MRI 检查的患者。
- MRI 采用帕金森指数(MRPI)作为指标,SPECT 采用特异性结合比(SBR),SBR 取左右两侧平均值。
诊断标准与关键数值
- MRPI 截断值 >11.6 时,敏感度 85.0%、特异度 100%、准确率 94.3%。
- SBR 截断值 <3.7 时,敏感度 95.0%、特异度 36.4%、准确率 58.5%。
- 20 例诊断为很可能 PSP 的患者中,15 例(75.0%)存在眼动功能障碍(p < 0.0001)。
临床应用与阅片要点
- 作者认为 SPECT 与 MRI 作用互补,联合使用可能有助于更有信心地做出 PSP 临床诊断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. Progressive supranuclear palsy (PSP) is listed as a core clinical feature in the Movement Disorder Society 2017 criteria, along with ocular motor dysfunction, postural instability, akinesia, and cognitive dysfunction. Imaging evidence shows predominant mid-brain atrophy and postsynaptic striatal dopaminergic degeneration as two supportive features. The purpose of this study was to investigate the diagnostic performance of 123I-N- ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane (123I-FP-CIT) SPECT by comparing it with evaluation of core clinical features and MRI in the diagnosis of PSP. MATERIALS AND METHODS. The study included 53 patients with clinically suspected PSP who had undergone 123I-FP-CIT SPECT and MRI examinations. MR parkinsonism index (MRPI) was used as the MRI index. For the 123I-FP-CIT SPECT index, specific binding ratio (SBR) was calculated as the average of the right and left SBRs. RESULTS. In regard to core clinical features, ocular motor dysfunction was present in 15 of 20 (75.0%) patients with the diagnosis of probable PSP (p < 0.0001). Calculation of the diagnostic performance of the imaging parameters showed that MRPI (cutoff > 11.6) had 85.0% sensitivity, 100% specificity, and 94.3% accuracy. SBR (cutoff < 3.7) had 95.0% sensitivity, 36.4% specificity, and 58.5% accuracy. CONCLUSION. Iodine-123-labeled FP-CIT SPECT has high sensitivity, and MRI has high specificity in the diagnosis of PSP. Because these tools have complementary roles, reach ing a more confident clinical diagnosis of PSP may be possible when both are used.
引用
- Sakamoto F, Shiraishi S, Kitajima M, et al. Diagnostic Performance of 123I-FPCIT SPECT Specific Binding Ratio in Progressive Supranuclear Palsy: Use of Core Clinical Features and MRI for Comparison. AJR Am J Roentgenol. 2020. PMID: 33021833. doi:10.2214/AJR.19.22436
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。