文献速递神经CT

机械取栓后双能CT物质分解图像早期预测最终梗死体积

Early prediction of final infarct volume with material decomposition images of dual-energy CT after mechanical thrombectomy.
PubMed 文献 · Neuroradiology · 2020-10-06

研究纳入50例大脑中动脉闭塞并接受机械取栓的患者,比较双能CT水物质密度图与60 keV单能图在取栓后早期预测最终梗死体积的能力,并与随访单能CT对照。水物质密度图与最终梗死体积相关性更高(r=0.86),且在梗死体积<70 ml的患者中一致性更好,提示物质分解可更早显示最终梗死范围。

要点

  • 双能CT水物质密度图较60 keV单能图更早显示梗死界定,平均体积60.7 ml对37.57 ml。
  • 水物质密度图与随访单能CT最终梗死体积相关性r=0.86,高于单能图的r=0.81。
  • 梗死体积<70 ml(33例,66%)时水物质密度图与单能图一致性更高(r=0.77对0.59)。

关键影像表现/征象

  • 水物质密度图显示梗死界定早于单能图,平均体积分别为60.7 ml(±74.9 ml)和37.57 ml(±76.7 ml)。
  • 水物质密度图与随访单能CT最终梗死体积的相关系数r=0.86(95%CI 0.76-0.92),单能图与单能CT的r=0.81(95%CI 0.69-0.89)。
  • 梗死体积<70 ml的患者(n=33,66%)中,水物质密度图与单能CT的r=0.77(95%CI 0.57-0.88),单能图与单能CT的r=0.59(95%CI 0.31-0.78)。

临床应用与阅片要点

  • 作者认为物质分解图像可更早显示最终梗死体积,可能有助于更早评估梗死范围和严重程度,并可能加快启动二级卒中预防。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Evaluation of water material density images (wMDIm) of dual-energy CT (DECT) for earlier prediction of final infarct volume (fiV) in follow-up single-energy CT (SECT) and correlation with clinical outcome.

METHODS: Fifty patients (69 years, ± 12.1, 40-90, 50% female) with middle cerebral artery (MCA) occlusions were included. Early infarct volumes were analyzed in monoenergetic images (MonoIm) and wMDIm at 60 keV and compared with the fiV in SECT 4.9 days (± 4) after thrombectomy. Association between infarct volume and functional outcome was tested by linear regression analysis.

RESULTS: wMDIm shows a prior visible infarct demarcation (60.7 ml, ± 74.9 ml) compared with the MonoIm (37.57 ml, ± 76.7 ml). Linear regression analysis, Bland-Altman plots and Pearson correlation coefficients show a close correlation of infarct volume in wMDIm to the fiV in SECT (r = 0.86; 95% CI 0.76-0.92), compared with MonoIm and SECT (r = 0.81; 95% CI 0.69-0.89). The agreement with SECT is substantially higher in patients with infarct volumes < 70 ml (n = 33; 66%). Coefficients were smaller with r = 0.59 (95% CI 0.31; 0.78) for MonoIm and SECT compared with r = 0.77 (95% CI 0.57; 0.88) for wMDIm and SECT. At admission, the mean NIHSS score and mRS were 17.02 (± 4.7) and 4.9 (± 0.2). mRS ≤ 2 was achieved in 56% at 90 days with a mean mRS of 2.5 (± 0.8) at discharge.

CONCLUSION: Material decomposition allows earlier visibility of the final infarct volume. This promises an earlier evaluation of the dimension and severity of infarction and may lead to faster initiation of secondary stroke prophylaxis.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Hopf-Jensen S, Anraths M, Lehrke S, et al. Early prediction of final infarct volume with material decomposition images of dual-energy CT after mechanical thrombectomy. Neuroradiology. 2020. PMID: 33025043. doi:10.1007/s00234-020-02563-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。