文献速递神经外周血管MRUS

多普勒颈内静脉血流量与磁共振成像检出横窦淤滞的关联

Associations Between Doppler Internal Jugular Vein Blood Flow and Transverse Sinus Stasis Detected by Magnetic Resonance Imaging.
PubMed 文献 · J Ultrasound Med · 2020-10-21

研究纳入80例脑MRI无静脉窦血栓征象的患者,按冠状位FLAIR横窦高信号分为慢流组与正常组,用多普勒超声测量双侧颈内静脉血流量。MRI慢流组颈内静脉总估计血流量546 mL/min,低于无慢流组的768 mL/min(P < .001);总血流量cutoff值590 mL/min、非优势侧cutoff值202 mL/min可用于区分两组。作者结论认为颈内静脉估计血流量低与同侧横窦淤滞的MRI证据相关。

要点

  • 冠状位FLAIR横窦高信号提示慢流时,应关注同侧颈内静脉多普勒血流量是否减低。
  • MRI慢流组颈内静脉总估计血流量546 mL/min,低于无慢流组的768 mL/min(P < .001)。
  • 区分两组的颈内静脉总血流量cutoff值为590 mL/min,非优势侧为202 mL/min。

核心结论

  • 颈内静脉估计血流量低与MRI所示同侧横窦淤滞相关。

研究设计与样本

  • 研究纳入80例18至80岁、脑MRI无静脉窦血栓征象的患者,按MRI表现分为慢流组与正常组。
  • 以冠状位液体衰减反转恢复序列横窦因信号丢失而呈高信号者归入慢流组,并用其他MRI脉冲序列及临床发现排除窦血栓。
  • 采用多普勒超声测量双侧颈内静脉血流量,以颈内静脉中心采样的时间平均血流速度与横截面积估算,将两侧中估计血流量较高者定义为优势颈内静脉。

关键影像表现/征象

  • MRI上冠状位液体衰减反转恢复序列横窦因信号丢失呈高信号,为慢流的影像征象。

诊断标准与关键数值

  • MRI慢流组颈内静脉总估计血流量为546 mL/min,无慢流组为768 mL/min,慢流组较低(P < .001)。
  • 非优势侧颈内静脉也可见类似表现。
  • 受试者工作特征分析确定区分两组的颈内静脉总估计血流量cutoff值为590 mL/min。
  • 非优势侧颈内静脉估计血流量cutoff值为202 mL/min。

临床应用与阅片要点

  • 阅读脑MRI时,对冠状位液体衰减反转恢复序列横窦高信号(信号丢失所致)者,可结合多普勒超声评估同侧颈内静脉估计血流量。
  • 颈内静脉总估计血流量590 mL/min、非优势侧202 mL/min为原文报告的区分慢流组与正常组的cutoff值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to compare the estimated internal jugular vein (IJV) volume flow with Doppler ultrasound in patients with slow flow in the transverse sinuses and normal transverse sinuses on brain magnetic resonance imaging (MRI).

METHODS: Eighty patients between the ages of 18 and 80 years who did not have any signs of sinus vein thrombosis on brain MRI were included. On MRI, cases with hyperintensity due to a signal void loss in the transverse sinuses in coronal fluid attenuation inversion recovery sequences were included in the slow-flow group. The presence of sinus thrombosis was excluded with other MRI pulse sequences and clinical findings. The participants were divided into 2 groups as having normal and slow flow according to MRI findings. Then bilateral IJV volume flow measurements were made by Doppler ultrasound. Bilateral volume flow was estimated by time-averaged blood flow velocities sampled in the center of the IJV, and IJV cross-sectional areas were measured. We defined the dominant IJV as the one having the higher estimated volume flow of the 2 sides.

RESULTS: Total estimated IJV blood flow was lower (P < .001) in patients with slow flow on MRI (546 mL/min) compared to those without (768 mL/min). A similar finding was seen for the nondominant IJV. In a receiver operating characteristic analysis, the cutoff value for the total estimated IJV volume flow was determined to be 590 mL/min, and the cutoff value for nondominant estimated IJV volume flow was determined to be 202 mL/min to distinguish between the groups.

CONCLUSIONS: Low estimated volume blood flow in the IJV is associated with MRI evidence of stasis in the ipsilateral transverse sinus.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. İlhan Z, Açıkgözoğlu S, Demir O, et al. Associations Between Doppler Internal Jugular Vein Blood Flow and Transverse Sinus Stasis Detected by Magnetic Resonance Imaging. J Ultrasound Med. 2020. PMID: 33085792. doi:10.1002/jum.15541

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。