成人II型房间隔缺损患者长期心脏适应的评估:一项心血管磁共振(CMR)研究
本研究用心血管磁共振比较35例II型房间隔缺损患者与40例对照,评估左向右分流对双心室容积、功能和心肌应变的影响。患者右室充盈增大、左室充盈不足,右室收缩功能受损,可能与室间隔纵向功能异常有关。
要点
- II型房间隔缺损患者右室舒张末期容积指数增大、左室减小,右室/左室比值升高。
- 患者右室整体纵向应变减低,室间隔纵向应变显著减低,右室游离壁纵向应变无显著差异。
- 分流严重程度与右室大小、每搏量、右房大小及肺动脉干直径相关,与功能和应变参数无关。
关键影像表现/征象
- 患者右室舒张末期容积指数152±42 ml/m2 vs 对照82±11 ml/m2,左室舒张末期容积指数72±16 ml/m2 vs 对照83±9 ml/m2,右室/左室舒张末期容积指数比值2.2±0.5 vs 对照1.0±0.1(均p<0.001)。
- 患者右室每搏量大于对照、左室每搏量小于对照(均p<0.001),右室射血分数有降低趋势(p=0.08)。
- 患者右室整体纵向应变减低(p=0.03),右室整体周向应变无显著差异。
- 患者室间隔纵向应变显著低于对照(p<0.001),右室游离壁纵向应变无显著差异。
诊断标准与关键数值
- 左向右分流Qp/Qs为2.2±0.6。
- 分流严重程度与右室大小、每搏量、右房大小及肺动脉干直径相关(均p<0.001),与功能和应变参数无关。
临床应用与阅片要点
- CMR电影成像可定量评估II型房间隔缺损患者双心室容积和功能改变,表现为右室过度充盈和左室充盈不足。
- 心肌应变分析显示右室整体纵向应变和室间隔纵向应变减低,提示室间隔纵向功能异常可能参与右室收缩功能受损。
- 分流严重程度与右室大小、每搏量、右房大小及肺动脉干直径相关,阅片时可关注这些结构改变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: In type II atrial septal defect (ASD) patients, the left-to-right (LR) shunt causes adaptation of the heart and circulation. The study objective was to evaluate with cardiovascular magnetic resonance imaging (CMR) the impact of LR shunt on left (LV) and right ventricular (RV) volumes, function, and myocardial strain.
METHODS: Thirty-five patients (42 ± 17 years, 17 male) were compared to a control group (n = 40). Cine imaging was used to calculate ventricular volumes and ejection fraction (EF), global longitudinal (GLS) and circumferential strain (GCS), and longitudinal free wall (FWS) and interventricular septal (IVS) strain. Phase-contrast imaging was used to calculate pulmonary flow to systemic flow ratio (Qp/Qs).
RESULTS: The LR shunt (Qp/Qs 2.2 ± 0.6) resulted in larger RV end-diastolic volume (EDVi) (152 ± 42 vs 82 ± 11 ml/m2), lower LV EDVi (72 ± 16 vs 83 ± 9 ml/m2), and higher RV/LV EDVi ratio (2.2 ± 0.5 vs 1.0 ± 0.1) than controls (all p < 0.001). Functionally, stroke volumes were larger in RV and lower in LV (both p < 0.001) with a strong trend toward lower RV EF in patients (p = 0.08). The LR shunt negatively impacted RV GLS (p = 0.03) but not RV GCS. Longitudinal IVS but not RV FWS were significantly lower in patients, i.e., p < 0.001, of longitudinal IVS. Shunt severity correlated with RV size and stroke volume, right atrial size, and pulmonary trunk diameter (all p < 0.001), but not with functional nor strain parameters.
CONCLUSION: Long-term cardiac adaptation in ASD patients, with RV overfilling and LV underfilling, has a negative impact on systolic RV performance, a phenomenon which likely can be attributed to longitudinal dysfunction of the interventricular septum.
KEY POINTS: • An LR shunt in type II ASD patients causes cardiac remodeling characterized by RV overfilling and conversely underfilling of the left ventricle. • At the long term, there is evidence of systolic dysfunction of the right ventricle in this group of patients. • Septal dysfunction underlies the observed impairment in RV function.
引用
- Hiraoka A, Symons R, Bogaert JA, et al. Assessment of long-term cardiac adaptation in adult patients with type II atrial septal defect : A cardiovascular magnetic resonance (CMR) study. Eur Radiol. 2020. PMID: 33037912. doi:10.1007/s00330-020-07364-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。