文献速递神经MR

联合3D FLAIR与T2加权(FLAIR3)成像灵敏检测多发性硬化幕下及上颈髓病灶

Sensitive Detection of Infratentorial and Upper Cervical Cord Lesions in Multiple Sclerosis with Combined 3D FLAIR and T2-Weighted (FLAIR3) Imaging.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-10-08

研究纳入30例多发性硬化患者,采集3D T2-FLAIR与3D T2加权图像并按FLAIR3公式合成,比较FLAIR3与3D T2-FLAIR对幕下及上颈髓病灶的检出。FLAIR3检出幕下病灶(均值4.6±3.6 vs 2.0±1.8,P<.001)和颈髓病灶(均值1.58±0.94 vs 0.46±0.45,P<.001)均显著多于3D T2-FLAIR,且评分者间信度显著提高。

要点

  • FLAIR3较3D T2-FLAIR检出更多幕下病灶(均值4.6±3.6 vs 2.0±1.8,P<.001)。
  • FLAIR3较3D T2-FLAIR检出更多颈髓病灶(均值1.58±0.94 vs 0.46±0.45,P<.001)。
  • 本队列中20%-30%(47%-67%)的患者幕下(颈髓)病灶仅见于FLAIR3。

诊断标准与关键数值

  • FLAIR3检出幕下病灶均值4.6±3.6 vs 3D T2-FLAIR 2.0±1.8,P<.001。
  • FLAIR3检出颈髓病灶均值1.58±0.94 vs 3D T2-FLAIR 0.46±0.45,P<.001。
  • 评分者间信度组内相关系数FLAIR3 0.77(95%CI 0.63-0.87)vs 3D T2-FLAIR 0.60(95%CI 0.40-0.76),P=.019。
  • 评分者内信度组内相关系数FLAIR3 0.86(95%CI 0.73-0.93)vs 3D T2-FLAIR 0.79(95%CI 0.61-0.89),P=.23。
  • 本队列中20%-30%(47%-67%)的多发性硬化受试者幕下(颈髓)病灶仅见于FLAIR3。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Infratentorial and spinal cord lesions are important for diagnosing and monitoring multiple sclerosis, but they are difficult to detect on conventional MR imaging. We sought to improve the detection of infratentorial and upper cervical cord lesions using composite FLAIR3 images.

MATERIALS AND METHODS: 3D T2-weighted FLAIR and 3D T2-weighted images were acquired in 30 patients with MS and combined using the FLAIR3 formula. FLAIR3 was assessed against 3D T2-FLAIR by comparing the number of infratentorial and upper cervical cord lesions per subject using the Wilcoxon signed rank test. Intrarater and interrater reliability was evaluated using the intraclass correlation coefficient. The number of patients with and without ≥1 visible infratentorial/spinal cord lesion on 3D T2-FLAIR versus FLAIR3 was calculated to assess the potential impact on the revised MS diagnostic criteria.

RESULTS: Compared with 3D T2-FLAIR, FLAIR3 detected significantly more infratentorial (mean, 4.6 ± 3.6 versus 2.0 ± 1.8, P < .001) and cervical cord (mean, 1.58 ± 0.94 versus 0.46 ± 0.45, P < .001) lesions per subject. FLAIR3 demonstrated significantly improved interrater reliability (intraclass correlation coefficient = 0.77 [95% CI, 0.63-0.87] versus 0.60 [95% CI, 0.40-0.76] with 3D T2-FLAIR, P = .019) and a tendency toward a higher intrarater reliability (0.86 [95% CI, 0.73-0.93] versus 0.79 [95% CI, 0.61-0.89], P = .23). In our cohort, 20%-30% (47%-67%) of the subjects with MS had ≥ 1 infratentorial (cervical cord) lesion visible only on FLAIR3.

CONCLUSIONS: FLAIR3 provides higher sensitivity than T2-FLAIR for the detection of MS lesions in infratentorial brain parenchyma and the upper cervical cord.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Gabr RE, Lincoln JA, Kamali A, et al. Sensitive Detection of Infratentorial and Upper Cervical Cord Lesions in Multiple Sclerosis with Combined 3D FLAIR and T2-Weighted (FLAIR3) Imaging. AJNR Am J Neuroradiol. 2020. PMID: 33033051. doi:10.3174/ajnr.A6797

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。