文献速递神经技术与安全MR

三维快速小角度激发(FLASH)序列在住院与急诊3T增强脑MRI中的应用:与三维磁化准备快速梯度回波(MPRAGE)序列的比较

3D fast low-angle shot (FLASH) technique for 3T contrast-enhanced brain MRI in the inpatient and emergency setting: comparison with 3D magnetization-prepared rapid gradient echo (MPRAGE) technique.
PubMed 文献 · Neuroradiology · 2020-10-28

回顾性分析110例住院/急诊3T脑MRI增强检查,比较49秒3D-FLASH与4分35秒3D-MPRAGE序列检测颅内强化病灶的诊断效能。两位神经放射科医师独立判读,结果显示两序列诊断准确率相似(MPRAGE 86.4%和88.1%,FLASH 88.2%和84.5%),且FLASH的磁敏感伪影和运动伪影更少(p<0.001)。

要点

  • 49秒3D-FLASH检测颅内强化病灶的诊断准确率与4分35秒3D-MPRAGE相似,两序列间无诊断准确率不一致。
  • 3D-FLASH的磁敏感伪影和运动伪影均显著少于3D-MPRAGE(p<0.001)。
  • 两序列检测强化病灶的阅片者间一致性均为充分(MPRAGE κ=0.76,FLASH κ=0.86)。

关键影像表现/征象

  • 3D-FLASH的颅内磁敏感伪影少于3D-MPRAGE(两位阅片者均p<0.001)。
  • 3D-FLASH的运动伪影少于3D-MPRAGE(两位阅片者均p<0.001)。
  • 两序列检测颅内强化病灶无序列间诊断准确率不一致(两位阅片者均无)。

诊断标准与关键数值

  • 3D-MPRAGE诊断准确率:阅片者1为86.4%,阅片者2为88.1%。
  • 3D-FLASH诊断准确率:阅片者1为88.2%,阅片者2为84.5%。
  • 阅片者内序列间一致性:阅片者1 κ=0.70(95%CI 0.60–0.81),阅片者2 κ=0.70(95%CI 0.59–0.82)。
  • 阅片者间序列内一致性:3D-MPRAGE κ=0.76(95%CI 0.66–0.86),3D-FLASH κ=0.86(95%CI 0.77–0.94)。

临床应用与阅片要点

  • 在住院与急诊3T脑MRI增强检查中,3D-FLASH可作为缩短采集时间并减少磁敏感及运动伪影的替代序列,其检测颅内强化病灶的诊断效能与3D-MPRAGE相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To retrospectively evaluate the diagnostic performance of a 1-min contrast-enhanced 3D-FLASH pulse sequence for detecting intracranial enhancing lesions compared to standard contrast-enhanced 3D-MPRAGE pulse sequence.

METHODS: Contrast-enhanced 3D-FLASH (acquisition time 49 s) and contrast-enhanced 3D-MPRAGE (4 min 35 s) pulse sequences were performed consecutively in 110 inpatient/emergency department 3T MRI brain examinations and analyzed by two independent neuroradiologist readers. For each sequence, the readers recorded (1) number of enhancing intracranial lesions; (2) intracranial susceptibility artifact (presence or absence; mm depth of intracranial signal loss); and (3) motion artifact (none, mild, moderate, severe). Inter and intra-reader agreement and reader accuracy relative to a reference standard were determined, and sequence comparison with respect to susceptibility and motion artifacts was performed.

RESULTS: There was substantial intra-reader, inter-sequence agreement [reader 1, κ = 0.70 (95% CI: [0.60, 0.81]); reader 2, κ = 0.70 (95% CI: [0.59, 0.82])] and substantial intra-sequence, inter-reader agreement [3D-MPRAGE assessment, κ = 0.76 (95% CI: [0.66, 0.86]); 3D-FLASH assessment, κ = 0.86 (95% CI: [0.77, 0.94]) for detection of intracranial enhancing lesions. For both readers, the diagnostic accuracy of 3D-FLASH and 3D-MPRAGE was similar (3D-MPRAGE: 86.4 and 88.1%; 3D-FLASH: 88.2 and 84.5%), with no inter-sequence diagnostic accuracy discordancy between the sequences for either reader. 3D-FLASH was associated with less susceptibility artifact (p < 0.001 both readers) and less motion artifact (p < 0.001 both readers).

CONCLUSION: On 3T brain MRI in the inpatient and emergency department setting, 1-min 3D-FLASH pulse sequence achieved comparable diagnostic performance to 4.5 min 3D-MPRAGE pulse sequence for detecting enhancing intracranial lesions, with reduced susceptibility and motion artifacts.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Patel SH, Batchala PP, Schallert K, et al. 3D fast low-angle shot (FLASH) technique for 3T contrast-enhanced brain MRI in the inpatient and emergency setting: comparison with 3D magnetization-prepared rapid gradient echo (MPRAGE) technique. Neuroradiology. 2020. PMID: 33118042. doi:10.1007/s00234-020-02590-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。