评价脑动静脉分流:并行成像时间飞跃法磁共振血管成像(TOF-MRA)与压缩感知TOF-MRA对比数字减影血管造影
本研究在3T MR设备上对56例患者行压缩感知(CS)TOF-MRA与并行成像(PI)TOF-MRA,比较两者检测和描述脑动静脉分流(AVS)的诊断准确度。CS-TOF-MRA与PI-TOF-MRA对颅内AVS检测均具有很高的敏感度和特异度,阅片者间对AVS血管构架特征的一致性为中等至良好。作者结论认为CS-TOF-MRA的诊断性能与PI-TOF-MRA相当,且扫描时间缩短至2.5分钟以内。
要点
- CS-TOF-MRA扫描时间为2分26秒,PI-TOF-MRA为5分19秒,加速倍数分别为6.5倍和3倍。
- 两位阅片者对颅内AVS检测的敏感度和特异度分别为97.3%、94.7%和100%、100%。
- CS-MRA与PI-MRA上AVS血管构架特征的阅片者间一致性为中等至良好。
关键影像表现/征象
- CS-TOF-MRA与PI-TOF-MRA对颅内AVS检测均具有很高的敏感度和特异度。
- CS-MRA与PI-MRA上颅内AVS血管构架特征的阅片者间一致性为中等至良好。
诊断标准与关键数值
- 阅片者1对颅内AVS检测的敏感度为97.3%、特异度为94.7%。
- 阅片者2对颅内AVS检测的敏感度为100%、特异度为100%。
- CS-TOF、PI-TOF与数字减影血管造影之间的一致性采用非加权和加权kappa统计量计算。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Time-of-flight (TOF)-MR angiography (MRA) is an important imaging sequence for the surveillance and analysis of cerebral arteriovenous shunt (AVS), including arteriovenous malformation (AVM) and arteriovenous fistula (AVF). However, this technique has the disadvantage of a relatively long scan time. The aim of this study was to compare diagnostic accuracy between compressed sensing (CS)-TOF and conventional parallel imaging (PI)-TOF-MRA for detecting and characterizing AVS.
METHODS: This study was approved by the institutional review board for human studies. Participants comprised 56 patients who underwent both CS-TOF-MRA and PI-TOF-MRA on a 3-T MR unit with or without cerebral AVS between June 2016 and September 2018. Imaging parameters for both sequences were almost identical, except the acceleration factor of 3× for PI-TOF-MRA and 6.5× for CS-TOF-MRA, and the scan time of 5 min 19 s for PI-TOF-MRA and 2 min 26 s for CS-TOF-MRA. Two neuroradiologists assessed the accuracy of AVS detection on each sequence and analyzed AVS angioarchitecture. Concordance between CS-TOF, PI-TOF, and digital subtraction angiography was calculated using unweighted and weighted kappa statistics.
RESULTS: Both CS-TOF-MRA and PI-TOF-MRA yielded excellent sensitivity and specificity for detecting intracranial AVS (reviewer 1, 97.3%, 94.7%; reviewer 2, 100%, 100%, respectively). Interrater agreement on the angioarchitectural features of intracranial AVS on CS-MRA and PI-MRA was moderate to good.
CONCLUSION: The diagnostic performance of CS-TOF-MRA is comparable to that of PI-TOF-MRA in detecting and classifying AVS with a reduced scan time under 2.5 min.
引用
- Sakata A, Fushimi Y, Okada T, et al. Evaluation of cerebral arteriovenous shunts: a comparison of parallel imaging time-of-flight magnetic resonance angiography (TOF-MRA) and compressed sensing TOF-MRA to digital subtraction angiography. Neuroradiology. 2020. PMID: 33063222. doi:10.1007/s00234-020-02581-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。