文献速递头颈神经MR

头颈部定量T1ρ MRI可鉴别鼻咽癌与鼻咽良性增生

Quantitative T1ρ MRI of the Head and Neck Discriminates Carcinoma and Benign Hyperplasia in the Nasopharynx.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-10-29

前瞻性纳入未分化型鼻咽癌患者与鼻咽良性增生者行T1ρ成像,比较直方图分析参数。鼻咽癌T1ρ均值、标准差及偏度均低于良性增生,标准差曲线下面积最高(0.95),提示定量T1ρ成像有潜力鉴别头颈部恶性、良性及正常组织。

要点

  • 鼻咽癌T1ρ标准差曲线下面积0.95,高于均值与偏度的0.72。
  • 鼻咽癌T1ρ均值62.14 ms低于良性增生65.45 ms,标准差12.60低于17.73 ms。
  • 鼻咽癌与良性增生峰度差异无统计学意义(P=.18)。

核心结论

  • 定量T1ρ成像有潜力鉴别头颈部的恶性、良性及正常组织。

研究设计与样本

  • 前瞻性研究,未分化型鼻咽癌患者及鼻咽良性增生者行T1ρ成像。
  • 鼻咽癌43例的直方图T1ρ测量值与41例良性增生者及正常组织(脑、肌肉、腮腺)比较,采用Mann-Whitney U检验。
  • 对有统计学意义的T1ρ测量值计算曲线下面积,采用受试者工作特征分析及Delong检验比较,P<.05为有统计学意义。

诊断标准与关键数值

  • 鼻咽癌与良性增生、鼻咽癌与正常组织的T1ρ测量值差异均有统计学意义(均P<.05)。
  • 鼻咽癌T1ρ均值62.14 ms低于良性增生65.45 ms,标准差12.60 ms低于17.73 ms,偏度0.61低于0.76(均P<.05)。
  • 鼻咽癌与良性增生峰度差异无统计学意义(P=.18)。
  • 鉴别鼻咽癌与良性增生时,T1ρ标准差的曲线下面积0.95最高,T1ρ均值与T1ρ偏度的曲线下面积均为0.72(均P<.05)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: T1ρ imaging is a new quantitative MR imaging pulse sequence with the potential to discriminate between malignant and benign tissue. In this study, we evaluated the capability of T1ρ imaging to characterize tissue by applying T1ρ imaging to malignant and benign tissue in the nasopharynx and to normal tissue in the head and neck.

MATERIALS AND METHODS: Participants with undifferentiated nasopharyngeal carcinoma and benign hyperplasia of the nasopharynx prospectively underwent T1ρ imaging. T1ρ measurements obtained from the histogram analysis for nasopharyngeal carcinoma in 43 participants were compared with those for benign hyperplasia and for normal tissue (brain, muscle, and parotid glands) in 41 participants using the Mann-Whitney U test. The area under the curve of significant T1ρ measurements was calculated and compared using receiver operating characteristic analysis and the Delong test, respectively. A P < . 05 indicated statistical significance.

RESULTS: There were significant differences in T1ρ measurements between nasopharyngeal carcinoma and benign hyperplasia and between nasopharyngeal carcinoma and normal tissue (all, P < . 05). Compared with benign hyperplasia, nasopharyngeal carcinoma showed a lower T1ρ mean (62.14 versus 65.45 × ms), SD (12.60 versus 17.73 × ms), and skewness (0.61 versus 0.76) (all P < .05), but no difference in kurtosis (P = . 18). The T1ρ SD showed the highest area under the curve of 0.95 compared with the T1ρ mean (area under the curve = 0.72) and T1ρ skewness (area under the curve = 0.72) for discriminating nasopharyngeal carcinoma and benign hyperplasia (all, P < .05).

CONCLUSIONS: Quantitative T1ρ imaging has the potential to discriminate malignant from benign and normal tissue in the head and neck.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Ai QYH, Chen W, So TY, et al. Quantitative T1ρ MRI of the Head and Neck Discriminates Carcinoma and Benign Hyperplasia in the Nasopharynx. AJNR Am J Neuroradiol. 2020. PMID: 33122214. doi:10.3174/ajnr.A6828

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。