最大模糊距离相位成像检测创伤性脑微出血优于当前影像实践
这项前瞻性研究纳入10名诊断为轻度创伤性脑损伤的运动员,在伤后2天、2周和2个月使用3T MR进行全脑T1 MPRAGE、T2 FLAIR、常规SWI和MAGPI多回波序列扫描。MAGPI-SWI在6名参与者中识别出脑微出血,而常规SWI因明显的畸变和磁化率伪影未能可靠识别这些微出血。
要点
- MAGPI-SWI可显示常规SWI因畸变和磁化率伪影而无法可靠识别的脑微出血。
- 6名参与者经MAGPI-SWI检出脑微出血,其中4名在FLAIR上可见并发挫伤。
- 常规SWI未能可靠识别任何一例MAGPI-SWI所见的脑微出血。
关键影像表现/征象
- 常规SWI因明显的畸变和磁化率伪影,未能可靠识别任何一例MAGPI-SWI所见的脑微出血。
- MAGPI-SWI在6名参与者中检出脑微出血,其中4名在FLAIR成像上可见并发挫伤的证据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Developed using a rigorous mathematic framework, Maximum AmbiGuity distance for Phase Imaging (MAGPI) is a promising phase-imaging technique that provides optimal phase SNR and reduced susceptibility artifacts. We aimed to test the potential of MAGPI over routinely used SWI in the detection of traumatic cerebral microbleeds in athletes diagnosed with mild traumatic brain injury.
MATERIALS AND METHODS: In this prospective study, 10 athletes (18-22 years of age, 3 women/7 men) diagnosed with mild traumatic brain injury were enrolled. Brain MRIs were performed using 3T MR imaging at 2 days, 2 weeks, and 2 months after head trauma. The imaging protocol included whole-brain T1 MPRAGE, T2 FLAIR, conventional SWI, and the MAGPI multiecho sequence. Phase images from MAGPI were put through a previously described SWI process to generate MAGPI-SWI. Conventional and MAGPI-SWI were assessed independently by a board-certified neuroradiologist for the presence of contusions and cerebral microbleeds. All participants had routine neuropsychological assessment and Visuo-Motor Tests.
RESULTS: At initial assessment, 4 of the participants had visuo-motor performance indicative of mild traumatic brain injury, and 4 participants had a Post-Concussion Symptom Scale score of >21, a threshold that has been used to define moderate impairment. Cerebral microbleeds were identified in 6 participants on MAGPI-SWI, 4 of whom had evidence of concurrent contusions on FLAIR imaging. None of these cerebral microbleeds were identified confidently on conventional SWI due to substantial distortion and susceptibility artifacts.
CONCLUSIONS: Optimal phase unwrapping with reduced susceptibility in MAGPI-SWI can clarify small microbleeds that can go undetected with routinely used conventional SWI.
引用
- Nael K, Dagher JC, Downs ME, et al. Maximum AmbiGuity Distance for Phase Imaging in Detection of Traumatic Cerebral Microbleeds: An Improvement over Current Imaging Practice. AJNR Am J Neuroradiol. 2020. PMID: 33033046. doi:10.3174/ajnr.A6774
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。