文献速递神经介入DSA

探讨影响脑动脉造影与脑动脉瘤栓塞辐射暴露的参数并基于手术复杂度建立典型值

Investigating the parameters that affect the radiation exposure and establishing typical values based on procedure complexity for cerebral angiography and brain aneurysm embolization.
PubMed 文献 · Neuroradiology · 2020-10-14

该单中心回顾性研究分析了2016年3月至2019年12月间348例脑动脉造影(CA)和脑动脉瘤栓塞(BAE)的临床参数与辐射暴露数据,以暴露参数中位数建立典型值(TV),发现男性、CA治疗血管数及BAE动脉瘤位置是影响患者辐射暴露的关键参数。

要点

  • CA的PKA,T典型值男性52 Gycm2、女性28 Gycm2;BAE男性113 Gycm2、女性75 Gycm2。
  • CA治疗血管数增加暴露显著升高,1支血管TV为20 Gycm2,5-6支为77 Gycm2。
  • BAE动脉瘤位置影响暴露,位置1组TV为55 Gycm2,位置2组为105 Gycm2。

核心结论

  • 男性、CA治疗血管数及BAE动脉瘤位置是影响CA和BAE术中患者辐射暴露的关键参数。

研究设计与样本

  • 单中心回顾性研究,回顾2016年3月至2019年12月间在单一神经放射学专科中心进行的348例检查的临床参数与暴露数据。
  • 典型值(TV)以总空气比释动能面积乘积(PKA,T)、患者入射参考点空气比释动能、透视时间及帧数的分布中位数得出。
  • 统计分析探讨CA中患者性别与治疗血管数、BAE中患者性别、动脉瘤位置与尺寸及治疗策略对暴露变异的影响。

诊断标准与关键数值

  • CA的PKA,T典型值:男性52 Gycm2 vs 女性28 Gycm2。
  • BAE的PKA,T典型值:男性113 Gycm2 vs 女性75 Gycm2。
  • CA按治疗血管数:1支血管TV为20 Gycm2 vs 5-6支血管TV为77 Gycm2。
  • BAE按动脉瘤位置分组:位置1组TV为55 Gycm2 vs 位置2组TV为105 Gycm2。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study is to investigate the parameters that affect the radiation exposure and to establish typical values (TV) based on procedure complexity for cerebral angiography (CA) and brain aneurysm embolization (BAE).

METHODS: Clinical parameters and exposure data were retrospectively reviewed for 348 examinations performed between March 2016 and December 2019 at a single specialized neuroradiology center. TV were derived as the median value of the distribution of exposure parameters such as total air kerma area product (PKA,T), air kerma at the patient entrance reference point, fluoroscopy time, and number of frames. A statistical analysis was conducted to investigate the exposure variability with patient's gender, number of treated vessels during CA and patient gender, aneurysm location and dimension, and treatment strategies during BAE.

RESULTS: Patient gender was associated with a significant increase in the exposure level for both CA and BAE. For CA, TV were in term of PKA,T of 52 Gycm2 for male vs. 28 Gycm2 for female patients. For BAE, these were 113 Gycm2 for male vs. 75 Gycm2 for female patients. Exposure levels increased significantly with the number of treated vessels in CA. TV were 20 Gycm2 for one vessel vs. 77 Gycm2 for 5-6 vessels CA. For BAE, aneurysm location was also a key factor that affects the patient exposure. TV were 55 Gycm2 for aneurysms grouped in location 1 vs. 105 Gycm2 for those grouped in location 2.

CONCLUSION: Male gender, number of treated vessels, and aneurysm location are key parameters affecting patient exposure during CA and BAE procedures.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Rizk C, Abi Chedid G, Salem C, et al. Investigating the parameters that affect the radiation exposure and establishing typical values based on procedure complexity for cerebral angiography and brain aneurysm embolization. Neuroradiology. 2020. PMID: 33057746. doi:10.1007/s00234-020-02580-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。