基于深度学习的计算机辅助检测提高颅内出血诊断准确性的研究
本研究纳入40例头颅CT数据集(正常16例、出血24例),由15名不同级别医师(5名认证放射科医师、5名放射科住院医师、5名实习医师)分别在无和有深度学习CAD辅助下进行两轮阅片。结果显示,使用CAD后所有医师的平均准确率从83.7%显著提高至89.7%(p < 0.001),平均品质因数从0.78提高至0.82(p = 0.004),阅片时间从68秒显著缩短至43秒(p < 0.001)。
要点
- 使用CAD后所有医师平均准确率从83.7%提高至89.7%(p < 0.001)。
- 认证放射科医师准确率无CAD时92.5%、有CAD时97.5%。
- 所有医师平均品质因数从0.78提高至0.82(p = 0.004)。
诊断标准与关键数值
- 患者水平评估中,所有医师平均准确率无CAD时83.7%、有CAD时89.7%(p < 0.001)。
- 认证放射科医师准确率无CAD时92.5%、有CAD时97.5%。
- 放射科住院医师准确率无CAD时82.5%、有CAD时90.5%。
- 实习医师准确率无CAD时76.0%、有CAD时81.0%。
- 所有医师平均品质因数无CAD时0.78、有CAD时0.82(p = 0.004)。
临床应用与阅片要点
- CAD辅助可提高不同级别医师检测颅内出血的准确率和品质因数。
- CAD辅助可缩短所有医师的阅片时间:无CAD时68秒 vs 有CAD时43秒(p < 0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To elucidate the effect of deep learning-based computer-assisted detection (CAD) on the performance of different-level physicians in detecting intracranial haemorrhage using CT.
METHODS: A total of 40 head CT datasets (normal, 16; haemorrhagic, 24) were evaluated by 15 physicians (5 board-certificated radiologists, 5 radiology residents, and 5 medical interns). The physicians attended 2 reading sessions without and with CAD. All physicians annotated the haemorrhagic regions with a degree of confidence, and the reading time was recorded in each case. Our CAD system was developed using 433 patients' head CT images (normal, 203; haemorrhagic, 230), and haemorrhage rates were displayed as corresponding probability heat maps using U-Net and a machine learning-based false-positive removal method. Sensitivity, specificity, accuracy, and figure of merit (FOM) were calculated based on the annotations and confidence levels.
RESULTS: In patient-based evaluation, the mean accuracy of all physicians significantly increased from 83.7 to 89.7% (p < 0.001) after using CAD. Additionally, accuracies of board-certificated radiologists, radiology residents, and interns were 92.5, 82.5, and 76.0% without CAD and 97.5, 90.5, and 81.0% with CAD, respectively. The mean FOM of all physicians increased from 0.78 to 0.82 (p = 0.004) after using CAD. The reading time was significantly lower when CAD (43 s) was used than when it was not (68 s, p < 0.001) for all physicians.
CONCLUSION: The CAD system developed using deep learning significantly improved the diagnostic performance and reduced the reading time among all physicians in detecting intracranial haemorrhage.
引用
- Watanabe Y, Tanaka T, Nishida A, et al. Improvement of the diagnostic accuracy for intracranial haemorrhage using deep learning-based computer-assisted detection. Neuroradiology. 2020. PMID: 33025044. doi:10.1007/s00234-020-02566-x