钆增强三维T1加权黑血MR成像用于检测急性视神经炎

Gadolinium-Enhanced 3D T1-Weighted Black-Blood MR Imaging for the Detection of Acute Optic Neuritis.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-10-29

回顾性分析51例疑似急性视神经炎患者的3T MR数据,比较钆增强三维T1加权黑血序列与眶部专用钆增强T1加权Dixon序列。30例确诊急性视神经炎,其中21例视神经对比增强病灶在两序列上均可检出,两序列敏感度均为70%、特异度90%或100%(取决于阅片者),图像质量、诊断信心及标准化对比噪声比无显著差异(P=.27)。结论认为黑血序列在检测急性视神经炎方面与Dixon序列准确性及定性/定量特征相当,有望缩短总成像时间。

要点

  • 钆增强三维T1加权黑血序列检测急性视神经炎的敏感度为70%,特异度为90%或100%(取决于阅片者)。
  • 黑血序列与眶部专用Dixon序列在图像质量、伪影、诊断信心及视对比增强方面评分相似。
  • 两序列标准化对比噪声比无显著差异(黑血1.76±1.07 vs Dixon 2.29±2.49,P=.27)。

核心结论

  • 钆增强三维T1加权黑血成像在检测急性视神经炎方面与眶部专用钆增强T1加权Dixon成像的准确性及定性/定量特征相当,使用时有潜力显著缩短患者总成像时间。

研究设计与样本

  • 回顾性分析51例有急性视神经炎症状患者的3T MR成像数据,包括全脑钆增强三维T1加权黑血序列和眶部专用冠状位2D或3D钆增强T1加权Dixon序列。
  • 由两名神经放射学家评估图像总体质量、伪影、诊断信心和视对比增强,并计算标准化对比噪声比。
  • 急性视神经炎的最终诊断基于临床表现、视觉诱发电位和光学相干断层扫描确立。

关键影像表现/征象

  • 51例中30例诊断为急性视神经炎,其中21例视神经出现对比增强病灶,在钆增强T1加权Dixon和钆增强T1加权黑血图像上均可检出。

诊断标准与关键数值

  • 钆增强T1加权Dixon和钆增强T1加权黑血序列检测急性视神经炎的准确率相同,敏感度为70%,特异度为90%或100%(取决于阅片者)。
  • 黑血序列平均标准化对比噪声比为1.76±1.07,Dixon序列为2.29±2.49,两者无显著差异(P=.27)。

临床应用与阅片要点

  • 在怀疑急性视神经炎时,钆增强三维T1加权黑血序列可与眶部专用钆增强T1加权Dixon序列同样用于检测视神经对比增强病灶。
  • 黑血序列有潜力显著缩短患者总成像时间。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: A 3D T1-weighted black-blood sequence was recently shown to improve the detection of contrast-enhancing lesions in the brain in patients with MS compared with a 3D T1-weighted MPRAGE sequence. We compared a contrast-enhanced 3D T1-weighted black-blood sequence with a dedicated orbital contrast-enhanced T1-weighted Dixon sequence in patients with acute optic neuritis.

MATERIALS AND METHODS: MR imaging data (3T) of 51 patients showing symptoms of acute optic neuritis were analyzed retrospectively, including whole-brain contrast-enhanced 3D T1-weighted black-blood and dedicated orbital coronal 2D or 3D contrast-enhanced T1-weighted Dixon sequences. Two neuroradiologists assessed the images for overall image quality, artifacts, diagnostic confidence, and visual contrast enhancement. Furthermore, the standardized contrast-to-noise ratio was calculated. The final diagnosis of acute optic neuritis was established on the basis of clinical presentation, visually evoked potentials, and optical coherence tomography.

RESULTS: Thirty of 51 patients were diagnosed with acute optic neuritis. Of those, 21 showed contrast-enhancing lesions in the optic nerves, similarly detectable on contrast-enhanced T1-weighted Dixon and contrast-enhanced T1-weighted black-blood images. Thus, the accuracy for each sequence was identical, with a resulting sensitivity of 70% and specificity of 90% or 100% (depending on the reader). Overall image quality, diagnostic confidence, visual contrast enhancement, and artifacts were rated similarly in contrast-enhanced 3D T1-weighted black-blood and dedicated orbital contrast-enhanced T1-weighted Dixon sequences. There was no significant difference (P = .27) in the mean standardized contrast-to-noise ratio between contrast-enhanced T1-weighted black-blood (1.76 ± 1.07) and contrast-enhanced T1-weighted Dixon (2.29 ± 2.49) sequences.

CONCLUSIONS: Contrast-enhanced 3D T1-weighted black-blood imaging is comparable in accuracy and qualitative/quantitative features with dedicated orbital contrast-enhanced T1-weighted Dixon imaging for the detection of acute optic neuritis. Therefore, when used, it has the potential to considerably shorten total patient imaging time.