文献速递神经骨肌技术与安全CT

死后X射线相位对比显微CT对人类脊髓和脊柱解剖的高空间分辨率三维成像

High-Spatial-Resolution Three-dimensional Imaging of Human Spinal Cord and Column Anatomy with Postmortem X-ray Phase-Contrast Micro-CT.
PubMed 文献 · Radiology · 2020-10-27

研究比较了死后X射线相位对比显微CT对Thiel防腐人脊柱样本与提取的福尔马林固定脊髓样本的成像质量,评估其提供保留组织的高空间分辨率三维神经影像的可行性。结果显示Thiel样本可呈现椎管内软组织对比及脊髓血管和神经,福尔马林固定脊髓样本灰白质对比更高,可显示深部髓质血管和神经元胞体。

要点

  • X射线相位对比显微CT可在微米级分辨率三维显示骨、神经组织和血管。
  • Thiel防腐脊柱样本虽神经组织退化,仍可呈现椎管内软组织对比和对比剂增强的脊髓血管。
  • 福尔马林固定游离脊髓样本灰白质对比更高,可显示深部髓质血管和神经元胞体。

核心结论

  • X射线相位对比显微CT可用于防腐人脊柱的详细容积解剖可视化,在微米级分辨率三维显示骨、神经组织和血管,无需外源性对比剂。

研究设计与样本

  • 研究于2015年8月至2019年8月进行,成像3例单侧灌注碘化血管对比剂的Thiel防腐人脊柱样本和3例提取的福尔马林固定脊髓样本,在同步辐射装置行死后成像。
  • 采用传播-based X射线相位对比显微CT,单色60-keV X射线,探测器像素尺寸为46-µm或8-µm,应用单距离相位检索算法后进行滤波反投影CT重建。

关键影像表现/征象

  • Thiel防腐样本的X射线相位对比显微CT在椎管内产生软组织对比,尽管Thiel防腐后神经组织明显退化。
  • Thiel防腐样本中,大体脊髓解剖、脊膜、对比剂增强的脊髓血管和脊神经与周围椎骨结构均良好呈现。
  • 福尔马林固定无骨脊髓样本的X射线相位对比显微CT产生更高的灰质与白质对比,并实现深部髓质血管和神经元胞体的微尺度可视化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Modern high-spatial-resolution radiologic methods enable increasingly detailed volumetric postmortem investigations of human neuroanatomy for diagnostic, research, and educational purposes. Purpose To evaluate the viability of postmortem x-ray phase-contrast micro-CT to provide tissue-conserving, high-spatial-resolution, three-dimensional neuroimaging of the human spinal cord and column by comparing quality of x-ray phase-contrast micro-CT images of nondissected Thiel-embalmed human spines with images of extracted formalin-fixed human spinal cords. Specific focus was placed on assessing the detection of micrometric spinal cord soft-tissue structure and vasculature. Materials and Methods In this study from August 2015 to August 2019, three Thiel-embalmed human spinal column samples, unilaterally perfused with an iodinated vascular contrast agent, and three extracted formalin-fixed spinal cord samples were imaged postmortem at a synchrotron radiation facility. Propagation-based x-ray phase-contrast micro-CT was used with monochromatic 60-keV x-rays and a detector with either 46-µm or 8-µm pixel sizes. A single-distance phase-retrieval algorithm was applied to the acquired CT projection images in advance of filtered back projection CT reconstruction. The influence on image quality of Thiel versus formalin embalming was examined, and images were qualitatively evaluated in terms of the value of their anatomic representations. Results The x-ray phase-contrast micro-CT of Thiel-embalmed samples resulted in soft-tissue contrast within the vertebral canal, despite evident nervous tissue deterioration after Thiel embalming. Gross spinal cord anatomy, spinal meninges, contrast agent-enhanced spinal vasculature, and spinal nerves were all well rendered alongside surrounding vertebral bone structure. The x-ray phase-contrast micro-CT of formalin-fixed boneless cords led to much higher gray versus white matter contrast and to microscale visualization of deep medullary vasculature and neuronal perikarya. Conclusion This work demonstrated the use of x-ray phase-contrast micro-CT for detailed volumetric anatomic visualization of embalmed human spines. The method provided three-dimensional display of bone, nervous tissue, and vasculature at microscale resolutions without exogenous contrast agents. © RSNA, 2020 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Barbone GE, Bravin A, Mittone A, et al. High-Spatial-Resolution Three-dimensional Imaging of Human Spinal Cord and Column Anatomy with Postmortem X-ray Phase-Contrast Micro-CT. Radiology. 2020. PMID: 33107800. doi:10.1148/radiol.2020201622

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。