指南与共识心血管儿科影像技术与安全MRCT

犬心脏磁共振标准化平面定义的建议

Recommendations for standardized plane definition in canine cardiac MRI.
指南 / 共识 · Vet Radiol Ultrasound · 2020-09-29

这项前瞻性实验研究在6只健康比格犬的CT扫描上模拟心脏磁共振检查,由6名操作者(3名放射科医生、1名心脏科医生、1名影像住院医师、1名技师)在2至4周内重复两次,引入标准化检查流程图并评估平面质量与所需时间。左心平面质量高、线性测量ICC为0.789-0.948,右心平面质量中等、ICC降至0.429-0.738;全程中位时间首次30分钟、第二次24分钟。

要点

  • 标准化心脏磁共振流程图可被具备横断面影像经验的放射科医生快速掌握。
  • 左心平面质量高、测量可重复性好(ICC 0.789-0.948),右心平面质量中等、可重复性较低(ICC 0.429-0.738)。
  • 完成全程检查的中位时间首次为30分钟(范围13-103分钟),第二次为24分钟(范围15-62分钟)。

诊断标准与关键数值

  • 左心线性测量的组内相关系数(ICC)范围为0.789-0.948,属好至优。
  • 右心线性测量的ICC范围降至0.429-0.738,属中等至差。
  • 左心平面质量评分为高,右心平面质量评分为中等。

临床应用与阅片要点

  • 作者引入的标准化心脏磁共振检查流程图可用于犬心脏磁共振的平面标准化。
  • 完成全程检查的中位时间首次为30分钟(范围13-103分钟),第二次为24分钟(范围15-62分钟),不同操作者间差异显著,且左侧始终短于右侧。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

With the growing interest in cardiac magnetic resonance imaging (cMRI), veterinary radiologists will increasingly be asked to use this modality to answer complex cardiological questions. Plane alignment is crucial for reproducible assessment of the heart. Anesthesia time is a limiting factor in cMRI. Aims of this prospective experimental study were to introduce a flow chart for standardized cMRI-examination in dogs, to test it for reproducibility using a cardiac CT simulation and to estimate time requirements needed to complete the examination accurately. Six operators (3 radiologists, 1 cardiologist, 1 imaging-resident, 1 technician) simulated a cMRI examination on CT-scans of 6 healthy Beagle dogs twice within two to four weeks. Assessment included qualitative and quantitative scoring of plane quality and time requirements. The quality of planes was high for the left and moderate for the right side of the heart. The intraclass correlation coefficient (ICC) of linear measurements of structures on the left was good to excellent (ICC-range: 0.789-0.948) but dropped to moderate to poor levels for the right side (ICC-range: 0.429-0.738). The median time required to complete a full examination was 30 (range: 13-103) min in the first and 24 (range: 15-62) min in the second evaluation. It differed significantly between operators and was consistently shorter for the left than for the right side. In conclusion, a new standardized scheme for cMRI can be quickly adopted by radiologists with some expertise in cross sectional imaging. Qualitative and quantitative results were highly reproducible for the left but less for the right side.

来源:Vet Radiol Ultrasound,查看原文。版权归原作者所有。

引用

  1. Dennler M, Baron Toaldo M, Makara M, et al. Recommendations for standardized plane definition in canine cardiac MRI. Vet Radiol Ultrasound. 2020. PMID: 32996225. doi:10.1111/vru.12911

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。