国际肠道超声节段活动评分[IBUS-SAS]的最佳采集与制定专家共识:克罗恩病肠道超声的信度与评分者间变异性研究
本研究通过德尔菲专家共识确定克罗恩病肠道超声的四个关键活动参数(肠壁厚度、肠壁分层、壁充血、炎性肠系膜脂肪),并经12位国际专家对30例盲法病例判读,建立国际肠道超声节段活动评分[IBUS-SAS],其组内相关系数[ICC]达0.97[0.95-0.99,p<0.001],显示极好信度。
要点
- 克罗恩病肠道超声评估应关注肠壁厚度、肠壁分层、壁充血和炎性肠系膜脂肪四个参数。
- 肠壁厚度[IBUS-SAS]的组内相关系数[ICC]为0.96[0.94-0.98],信度几乎完美。
- 国际肠道超声节段活动评分[IBUS-SAS]的ICC为0.97[0.95-0.99,p<0.001],信度极好。
关键影像表现/征象
- 德尔菲共识确定四个关键参数:肠壁厚度[BWT]、肠壁分层、壁充血(彩色多普勒成像)和炎性肠系膜脂肪。
- 盲法判读显示每个变量均呈现中等至相当的信度。
- 建立了最佳标准化图像和动态剪辑采集方案。
诊断标准与关键数值
- 肠壁厚度[BWT]的组内相关系数[ICC]为0.96[0.94-0.98],几乎完美。
- 国际肠道超声节段活动评分[IBUS-SAS]的ICC为0.97[0.95-0.99,p<0.001],几乎完美。
- 四个参数均与整体疾病活动评估相关,并纳入最终评分。
临床应用与阅片要点
- 采用标准化图像和动态剪辑采集方案获取肠道超声图像。
- 评估克罗恩病肠道节段活动时,应测量肠壁厚度、观察肠壁分层、彩色多普勒评估壁充血及炎性肠系膜脂肪。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND AIMS: Intestinal ultrasound [IUS] is an accurate, patient-centreed monitoring tool that objectively evaluates Crohn's disease [CD] activity. However no current, widely accepted, reproducible activity index exists to facilitate consistent IUS identification of inflammatory activity. The aim of this study is to identify key parameters of CD inflammation on IUS, evaluate their reliability, and develop an IUS index reflecting segmental activity.
METHODS: There were three phases: [1] expert consensus Delphi method to derive measures of IUS activity; [2] an initial, multi-expert case acquisition and expert interpretation of 20 blinded cases, to measure inter-rater reliability for individual measures; [3] refinement of case acquisition and interpretation by 12 international experts, with 30 blinded case reads with reliability assessment and development of a segmental activity score.
RESULTS: Delphi consensus: 11 experts representing seven countries identified four key parameters including: [1] bowel wall thickness [BWT]; [2] bowel wall stratification; [3] hyperaemia of the wall [colour Doppler imaging]; and [4] inflammatory mesenteric fat. Blind read: each variable exhibited moderate to substantial reliability. Optimal, standardised image and cineloop acquisition were established. Second blind read and score development: intra-class correlation coefficient [ICC] for BWT was almost perfect at 0.96 [0.94-0.98]. All four parameters correlated with the global disease activity assessment and were included in the final International Bowel Ultrasound Segmental Activity Score with almost perfect ICC (0.97 [0.95-0.99, p <0.001]).
CONCLUSIONS: Using expert consensus and standardised approaches, identification of key activity measurements on IUS has been achieved and a segmental activity score has been proposed, demonstrating excellent reliability.
引用
- Novak KL, Nylund K, Maaser C, et al. Expert Consensus on Optimal Acquisition and Development of the International Bowel Ultrasound Segmental Activity Score [IBUS-SAS]: A Reliability and Inter-rater Variability Study on Intestinal Ultrasonography in Crohn's Disease. J Crohns Colitis. 2021. PMID: 33098642. doi:10.1093/ecco-jcc/jjaa216
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。